Rinnai TANKLESS WATER HEATER V53E Operation And Installation Manual

Rinnai TANKLESS WATER HEATER V53E Operation And Installation Manual

Tankless water heater
Hide thumbs Also See for TANKLESS WATER HEATER V53E:
Table of Contents

Advertisement

V53i
only
ANS Z21.10.3
CSA 4.3
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING
result causing property damage, personal injury or death.
- Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
Tankless Water Heater
Operation and Installation Manual
V53i ..................... REU-VB2020FFU-US
V53e .................... REU-VAM1620W-US
Table of Contents ..................... 2
Operating Instructions .............. 5
Maintenance .......................... 12
Error Codes ............................ 13
Consumer Support ................. 44
French Version ....................... 47
Register your product at www.rinnairegistration.com or
call 1-866-RINNAI1 (746-6241)
If the information in these instructions is not
followed exactly, a fire or explosion may

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TANKLESS WATER HEATER V53E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Rinnai TANKLESS WATER HEATER V53E

  • Page 1: Table Of Contents

    — Installation and service must be performed by a qualified ● installer, service agency or the gas supplier. CSA 4.3 Tankless Water Heater Operation and Installation Manual V53i ... REU-VB2020FFU-US V53e ... REU-VAM1620W-US Certified for installation in manufactured (mobile) homes.
  • Page 2: Table Of Contents

    State Regulations ... 46 French Version ... 47-63 V53i & V53e Operation and Installation Manual Manual draining of the water heater ... 22 Running a low volume of water through the water heater to prevent freezing... 22 When the water heater or external piping has frozen ...
  • Page 3: V53I

    (mobile) homes * Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice. The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value listed is for the purpose of input adjustment.
  • Page 4: Consumer Safety Information

    • Power Failure: The appliance will cut off the gas if it loses electrical power. The Rinnai water heater is one of the most advanced water heaters available. It provides a continuous supply of hot water at a preset temperature. This...
  • Page 5: Operating Instructions

    Used on this model to set the clock or sound volume. Indicates that hot water is being supplied (i.e. a hot water tap is open). Used to turn the water heater ON or OFF. Allows the temperature controller to be in an energy saving mode.
  • Page 6: Temperature Controllers - Models

    ON/OFF Button * Requires the transceiver, MC- 502RC-1US-M, to be connected to the water heater. Refer to the MC-502RC-1US-S manual and the Wireless Controller Installation Instructions for complete details on features, operation, and installation. MC-91-1US & MCC-91-1US MC-502RC-1US-S * (Wireless) V53i &...
  • Page 7: Temperature Controllers - Models

    Temperature Controllers - Models Dimensions (inches): 8.0 W x 4.125 H x 0.875 D The BC-100V controller is water resistant. Avoid splashing the controller. NOTICE In Use Indicator Priority Button and Indicator Call Clock Temperature Selection Dimensions (inches): 5.0 W x 4.75 H x 0.75 D In Use Indicator Temperature...
  • Page 8: How To Set The Temperature

    The green Priority light will glow indicating that this controller is controlling the temperature and that the Rinnai water heater is ready to supply hot water. The priority can only be changed while no hot water is running.
  • Page 9: Temperature Controller Settings

    Water temperatures over 125º F (52º C) can cause severe burns or scalding. Refer to the Danger Alert on water temperatures. Rinnai shall not, in any event, be liable for damages resulting from such misuse or misapplication.
  • Page 10: Using The Water Smart / Bath Fill Function

    The green Priority light will glow indicating that this controller is controlling the temperature and that the Rinnai water heater is ready to supply hot water. 2. Press the “Water Smart Bath Fill” button to set the water volume and temperature.
  • Page 11: Filling The Tub

    Bath Fill button.” 4. Turn off the bath hot water tap and push the Bath Fill button. The water heater will not allow hot water to flow from any source until the “Water Smart / Bath Fill” button is pushed.
  • Page 12: Maintenance

    Maintenance WARNING Turn off the electrical power supply, the manual gas valve and the manual water control valve whenever servicing the unit. Repairs and maintenance should be performed by a qualified service technician. The appliance should be inspected annually by a qualified service technician. Verify proper operation after servicing.
  • Page 13: Error Codes

    The Rinnai water heater has the ability to check its own operation continuously. If a fault occurs, an error code will flash on the display in the front panel and on the temperature controller if installed. This assists with diagnosing the fault and may enable you to overcome a problem without a service call. Please identify the code displayed when inquiring about service.
  • Page 14 Code Fault Thermal Fuse Over Temperature Warning Burner Sensor Error Outgoing Water Temperature Sensor Fault Heat Exchanger Outgoing Temperature Sensor Fault Combustion Air Temperature Sensor Fault Modulating Solenoid Valve Signal Abnormal Combustion Fan Failure Water Flow Control Fault Solenoid Valve Circuit Fault Flame Sensing Device Fault...
  • Page 15: Trouble Shooting For Common Issues

    Off” button press the ▲ button. The last 9 error codes will flash one after the other. To exit this mode press the “On/Off” and ▲ button as before. To display the water flow through the water heater press and hold the ▲ button for 2 seconds and without releasing the ▲ button press the “On/Off” button.
  • Page 16: Clean Thermistors

    Open both service valves (V1 and V2) on the hot water and cold water lines. Operate the pump and allow the cleaning solution to circulate through the water heater for 1 hour at a rate of 4 gallons per minute (15.1 liters per minute).
  • Page 17: V53I

    Rinnai highly recommends all installers attend a product knowledge class. For information on a Rinnai Training Course or for questions on installation call 1-800-621-9419. General Instructions WARNING Do not use substitute materials.
  • Page 18: Clearances From Appliance

    Ensure that the attachment strength is sufficient to support the weight. Refer to the weight of the water heater in the Specifications section. NOTE: Rinnai water heaters should be installed in an upright position. Do not install upside down or on it side. V53e...
  • Page 19: Electrical Connection

    The wiring diagram is located on the Technical Sheet attached to the inside of the front cover. The water heater must be electrically grounded in accordance with local codes, or in the absence of local codes with the National Electrical Code, ANSI/NFPA 70 and/or the CSA C22.1, Canadian Electrical Code.
  • Page 20: Pipe Sizing Procedure - Example

    Gas Piping Pipe Sizing Procedure - Example The gas supply must be capable of handling the entire gas load at the location. Gas line sizing is based on gas type, the pressure drop in the system, the gas pressure supplied, and gas line type. For gas pipe sizing in the United States, refer to the National Fuel Gas Code, NFPA 54.
  • Page 21: Water Piping General Instructions

    • Ensure that the water filter on the Rinnai water heater is clean and installed. • The relief valve should be added to the hot water outlet line and near the hot water outlet according to the manufacturer’s instructions.
  • Page 22: Freeze Protection Methods

    If the water heater is not going to be used during a period of possible freezing weather, it is recommended that the water inside the water heater be drained.
  • Page 23: Freeze Protection Piping

    In the event of a power failure at temperatures below freezing the water heater should be drained of all water to prevent freezing damage. The unit may be drained manually. However, Rinnai highly recommends that drain down solenoid valves be installed that will automatically drain the unit if power is lost.
  • Page 24: Error Indication Or Air Handler Control Switch

    Error Indication or Air Handler Control Switch (V53i) When using the Rinnai water heater with an Error Indication Switch, switch No. 4 in the bank of 8 switches should be in the off position. This is the default position. To connect the water heater to the Rinnai Air Handler, the Control Switch is necessary to function as the electrical connection.
  • Page 25: Recommended Piping For Circulation Systems

    Pump to be of bronze or stainless construction. IMPORTANT: Connect the building return line to the hot water supply line as close as possible to the Rinnai Water Heater. 3/4" Ball Valve 3/4" Union Check Valve Pressure Relief Valve...
  • Page 26: Optional Piping For Circulation Systems

    The pump should be sized to overcome the pressure loss through the Rinnai water heater, supply and return plumbing. Refer - ence the Rinnai Hot Water System Design Manual, Pump Sizing for Circulation. Pump to be of bronze or stainless construc - tion.
  • Page 27: Venting Instructions (V53I) Intake / Exhaust Guidelines

    NOTICE If it becomes necessary to access an enclosed vent system for service or repairs, Rinnai is not responsible for any costs or difficulties in accessing the vent system. Warranty does not cover obtaining access to an enclosed vent system.
  • Page 28: Maximum Vent Length

    Blocked flue error codes and shutdowns may result if switch no. 1 is not in the correct position. Vent Products Listed and Tested Vent Products for V53i ... REU-VB2020FFU-US Manufacturer Rinnai/Ubbink Heat-Fab Metal-Fab Vent Manufacturer Contact Information for Installation Instructions and Parts Lists: Rinnai/Ubbink...
  • Page 29: Flue Installation - Concentric Venting (V53I)

    (or replace with a male vent top). 5. Install the 4 screws at the vent top and tighten the 4 screws at the bracket. Secure the first vent component to the water heater Securing Screw with one self-tapping screw at the hole located above the condensate collector.
  • Page 30: Flue Terminal Clearances (Ans Z21.10.3, Csa 4.3 )

    Flue Terminal Clearances ( Description Clearance above grade, veranda, porch, deck, or balcony Clearance to window or door that may be opened Clearance to permanently closed window Vertical clearance to ventilated soffit, located above the terminal within a horizontal distance of 2 feet (61 cm) from the center line of the terminal Clearance to unventilated soffit Clearance to outside corner...
  • Page 31: Additional Clearances (V53I)

    • Avoid termination locations near commercial cooking exhaust. Vent terminal (represents concentric vent terminal) 12" (0.30 m ) to an inside corner (0.30 m) between Rinnai terminals at same level INSIDE CORNER (1.52 m) between 60" Rinnai terminals at different levels (0.91 m) to ventilated...
  • Page 32: Additional Clearances (V53E)

    Additional Clearances (V53e) Local codes supersede these clearances. • Avoid termination locations near a dryer vent. • Avoid termination locations near commercial cooking exhaust. V53i & V53e Operation and Installation Manual...
  • Page 33: Connecting Multiple Water Heaters

    MSA-2S. The V53e can use Rinnai pressure activation valves (PVA’s) can be used to manifold 2 to 5 Rinnai water heaters in order to produce a stable water temperature and allow the water heaters to run efficiently. Water heaters will turn on as necessary to meet the demand for hot water.
  • Page 34: High Altitude Installations

    Technicien d'entretien qualifié. WARNING 1. Turn off the power source and gas supply to the water heater / Coupez l`alimentation de gaz et électrique. 2. Remove the front cover from the water heater/ Enlever la couverture de devant du chauffe-eau.
  • Page 35: Temperature Controller Installation Location

    Configurations A maximum of 4 temperature controllers, including wired and wireless, can be installed for a water heater or bank of water heaters. Controllers can only be wired in parallel. Controllers cannot be wired in series.
  • Page 36: Mounting The Controller (V53I)

    2. 7. Disconnect the power from the Rinnai water heater. 8. Remove the cover of the Rinnai water heater. 9. Remove the plastic cover from the PCB and electrical connections. 10. Thread the cable through the access hole at...
  • Page 37: Mounting The Controller (V53E)

    1. Determine a suitable location for the controller. 2. Make three holes in the wall as shown. 3. Run the cable between the controller and the Rinnai water heater or the controller and another controller. 4. Remove the face plate from the temperature controller using a screwdriver.
  • Page 38: For Your Safety Read Before Operating

    Operating Instructions FOR YOUR SAFETY READ BEFORE OPERATING WARNING A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. B. BEFORE OPERATING smell all around the appliance area for gas.
  • Page 39: Technical Data

    Pressure Drop Curve Outlet Flow Data V53i & V53e Operation and Installation Manual Technical Data Water Flow (gpm) V53i V53e delta T - Temperature Rise (ºF) V53e V53i...
  • Page 40: Space Heating

    Iron Components Do not use Rinnai water heaters directly for space heating applications involving iron radiators or applications with any iron components. Iron components may oxidize creating rust that will clog the inlet filter of the Rinnai water heater. V53i & V53e Operation and Installation Manual...
  • Page 41: Dimensions

    Dimensions V53i HOT WATER OUTLET DESCRIPTION Width Depth * Height - Unit Height - with brackets Hot Water Outlet - from wall * Hot Water Outlet - from center Cold Water Inlet - from wall * Cold Water Inlet - from center Gas Connection - from wall * Gas Connection - from center From base to gas connection...
  • Page 42: Ladder Diagrams

    Ladder Diagram (for V53i) V53i & V53e Operation and Installation Manual...
  • Page 43: Ladder Diagrams

    Ladder Diagram (for V53e) V53i & V53e Operation and Installation Manual...
  • Page 44: Consumer Support

    Limited Warranty What is covered? This Warranty covers any defects in materials or workmanship when the product is installed and operated according to Rinnai written installation instructions, subject to the terms within this Limited Warranty document. This Warranty applies only to products that are installed correctly.
  • Page 45: Limited Warranty

    Replacement of the product may be authorized by Rinnai only. Rinnai does not authorize any person or company to assume for it any obligation or liability in connection with the replacement of the product. If Rinnai determines that repair of a product is not possible, Rinnai will replace the product with a comparable product at Rinnai’s discretion.
  • Page 46: State Regulations

    NOTICE BEFORE INSTALLATION Rinnai direct-vent appliance must be installed by a state qualified or licensed contractor and a properly trained Rinnai Installer. If you are not properly trained, you must not install this unit. IMPORTANT: In the State of Massachusetts (248 CMR 4.00 & 5.00)
  • Page 47: French Version

    Pour une traduction complète du manuel en français, vous pouvez le télécharger du site Web de www.rinnai.us. AVERTISSEMENT : Assurez-vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d'incendie ou d'explosion ou pour éviter tout dommage matériel, toute blessure ou la mort.
  • Page 48: Instructions D'utilisation

    Rinnai est prêt à fournir de l'eau chaude. La préséance d'un contrôleur sur les autres ne peut se modifier que s'il n'y a pas d'eau chaude qui coule.
  • Page 49: Plages De Température Avec Un Contrôleur De Température

    à une température sûre. Arroser des températures plus de 125º F (52º C) peut causer des brûlures ou scalding sévère. Se référer à l'Alerte de Danger sur les températures d'eau. Rinnai ne fait pas, en tout cas, être responsable des dommages qui résultent de tel usage impropre ou tel mauvais usage.
  • Page 50: Entretien

    Entretien AVERTISSEMENT Coupez l'alimentation électrique, et fermez l'arrivée de gaz et d'eau à leur vanne de coupure manuelle avant toute intervention sur l'unité. Les réparations ne doivent être effectuées que par un technicien de service qualifié. Cet appareil doit être inspecté annuellement par un technicien de service qualifié.
  • Page 51: Instructions D'installation

    Gardez la zone d'aspiration d'air exempte de produits chimiques comme chlore ou agent de blanchiment qui produisent des fumées. Ces fumées pourraient endommager des composants et réduire la durée de service de votre appareil. • Pour la conversion de type de gaz, contactez Rinnai.
  • Page 52: Écartements Par Rapport À L'appareil

    Reportez-vous au poids des modèles de chauffe-eau dans la section des spécifications. Remarque : Les chauffe-eau de Rinnai doit être installé dans une position verticale. N'installez pas à l'envers ou sur ce côté. V53e...
  • Page 53: Installation À Altitude Élevée

    Une vanne manuelle de coupure de gaz doit être placée sur la conduite d'alimentation en gaz en amont du chauffe -eau Rinnai. Un raccord union peut être utilisé sur la connexion au-dessus de la vanne de coupure pour pouvoir ultérieurement intervenir sur l'unité en la déconnectant.
  • Page 54: Tuyauterie D'eau

    être connecté à un appareil utilisé auparavant comme chauffage et fourniture d’eau non potable. • Le filtre d’eau du chauffage Rinnai dout être propre et installé. • La soupape de sûreté doit être actionnée manuellement au moins une fois par an pour vérifier qu'elle est toujours fonctionnelle.
  • Page 55: Tuyauterie Recommandée Pour Installation De Base

    Confer Solenoid Valve Électrovanne with local building officials before installation. Liste d'équipement Rinnai Rinnai Equipment List Chauffe-eau Rinnai Rinnai Water Heaters Kit RIK (optionnel) (raccords 3/4 po (19 mm) RIK-KIT (Optional) comprenant : (3/4" Fittings Include: 2 unions, 2 vannes à...
  • Page 56: Instructions De Ventilation (V53I) Consignes Pour Aspiration/Évacuation

    AVIS S'il devient nécessaire d'accéder à un circuit de mise à l'air libre inclus pour le service ou les réparations, Rinnai n'est pas responsable d'aucuns coûts ou difficulté en accédant au circuit de mise à l'air libre. La garantie ne couvre pas obtenir l'accès à...
  • Page 57: Longueur Maximum De Ventilation

    Contacts avec les constructeurs de ventilation pour des informations d'installation et de liste de pièces : Rinnai/Ubbink Téléphone : 800-621-9419 Fax : 678-829-1666 Site Web : www.rinnai.us Nombre de coudes à 90° 29 ft 3 23 ft 4 (8.8 m) (7.0 m)
  • Page 58: Espacements Pour Terminaison De Cheminée

    Réf. Description Espace au dessus de niveau du sol, véranda, porche, plate-forme ou balcon Écartement par rapport à fenêtre ou porte qui peut s'ouvrir Écartement par rapport à fenêtre toujours fermée Espacement vertical par rapport à combles ventilés, situés au-dessus de la terminaison à une distance horizontale de 2 ' (61 cm) de la ligne centrale de terminaison Espacement vertical par rapport à...
  • Page 59: Installation De Conduit De Cheminée (V53I)

    Installation de conduit de cheminée (V53i) Horizontal Termination without using the Condensate Collector AVERTISSEMENT Si un collecteur de condensat n'est pas utilisé, le tuyau de drainage doit être capuchonnée pour éviter que gaz d'échappement et condensat n'entrent dans le bâtiment. Ce capuchon est livré...
  • Page 60: Instructions De Mise En Marche

    Instructions d'utilisation À LIRE AVANT LA MISE EN SERVICE POUR VOTRE SÉCURITÉ AVERTISSEMENT Cet appareil ne comporte pas de veilleuse. Il est muni d’un dispositif d’allumage qui allume automatiquement le brûleur. Ne tentez pas d’allumer la veilleuse manuellement. AVANT DE FAIRE FONCTIONNER, reniflez tout autour de l’appareil pour déceler une odeur de gaz.
  • Page 61: Diagramme En Escalier

    Diagramme en escalier V53i PHASE CONTACT DE FUSIBLE 5 A DÉTECTION DE GEL ANTI-FOUDRE VARISTOR VARISTOR TERRE RELAIS 1 ALIMENTATION À DÉCOUPAGE 170 V CC 12,6 V 5 V CC DÉTECTEUR D'ÉCOULEMENT CIRCUIT DÉTECTEUR D'ÉCOULEMENT DISPOSITIF DE CON- TRÔLE D'ÉCOULEMENT CIRCUIT DISPOSITIF DE CONTRÔLE D'ÉCOULEMENT UNITÉ...
  • Page 62: Support À La Clientele

    Cette garantie couvre tous défauts dus aux matériaux et à la main d'œuvre quand le produit a été installé et utilisé en suivant les instructions écrites d'installation de Rinnai, dans les termes décrits dans ce document de garantie limitée. Cette garantie s'applique seulement aux produits qui sont installés correctement.
  • Page 63: Garantie Limitée

    Rinnai le remplacera par un produit comparable, à sa discrétion. Si un composant ou un produit retourné à Rinnai est trouvé sans défaut du aux matériaux ou à la main d'œuvre, ou qu'il est déterminé qu'il a été...
  • Page 64 (VAM1620W, VB2020FFU) U287-1821(00) © 2010 Rinnai America Corporation Printed in Japan...

This manual is also suitable for:

V53iReu-vb2020ffu-usReu-vam1620w-us

Table of Contents