Infinity HD250i Infinity HD200 Infinity HD200i Efficiency24 How to use and install Rinnai continuous flow water heaters This appliance shall be installed in accordance with: • Manufacturer’s Installation Instructions • Current AS/NZS 3000, AS/NZS 3500 & NZS 5261 • Local Regulations and Municipal Building Codes...
OPERATING THE SHOWER SAVER / BATH FILL FUNCTION ............... 13 COMBINING UNIVERSAL AND DELUXE CONTROLLERS ..............14 TROUBLESHOOTING....................15 WARRANTY STATEMENT - HOT WATER PRODUCTS .........16 WARRANTY CONDITIONS..................17 INSTALLATION MANUAL ..................18 ACCESSORIES ......................32 CONTACT INFORMATION ..................33 Rinnai New Zealand Operation Manual...
REGULATORY INFORMATION Your Rinnai Continuous Flow water heater complies with NZS5262. A declaration to this effect can be found on the Energy Safety Service website; www.ess.govt.nz. This Appliance must be installed correctly by an authorised person. The installation of gas, water, and electricity must conform to local regulations.
Congratulations on purchasing the latest technology temperature controlled Rinnai continuous flow water heating system. • The Rinnai Infinity and Infinity HD products NEVER RUN OUT of hot water. Whilst electricity, water and gas supplies are connected, hot water is available whenever hot water taps are open. •...
Drain*: applies only to the Efficiency (REU-K2430WG) model. Rinnai New Zealand Operation Manual...
Page 6
Controller will result default water heater causing the water to go cold. temperature of 50°C being selected. This is a Someone maybe in the middle of having a safety feature. shower or filling a bath. Rinnai New Zealand Operation Manual...
OPERATION WITHOUT CONTROLLERS Rinnai Infinity and Infinity HD continuous flow water heater products do not use a pilot light. When installed and operated without water controllers, the opening of any hot water tap will automatically start the appliance. Once water is flowing through the appliance the burner will be ignited by electronic ignition.
Kitchen 50°C ~ 55°C* Shower 37°C ~ 43°C, Bath fill 39°C ~ 45°C * Temperature may not be available on all installations. Rinnai water heaters can be programmed to deliver higher temperatures via the kitchen water controller. Contact Rinnai for more details.
43°C. In addition, transfer of 'priority' between NOTE controllers is not possible. These are safety features. The 'beep' sound can be muted by pressing the 'Hot water temp' Up Down buttons simultaneously for more than 3 seconds. Rinnai New Zealand Operation Manual...
The ‘in use’ indicator will also go out. The burner will ignite again once the outgoing hot water temperature falls to that shown on the digital monitor (or the pre-set limit of the appliance). Rinnai New Zealand Operation Manual...
The clock is a 12 hour AM/PM style display. To set the time press the 'Clock' button once, the Clock clock digits in the digital monitor will flash AM 12:00 in the clock setting mode. Rinnai New Zealand Operation Manual...
Whilst hot water outlets are open the set temperature may be lowered. However they cannot then be raised above 43°C. In addition transfer of 'priority' between NOTE controllers is not possible. These are safety features. Rinnai New Zealand Operation Manual...
NOTE buttons simultaneously for more than 3 seconds. This can be done for each Water Controller. To return to original settings, repeat this step. Avoid getting water in the speaker as this may cause damage. Rinnai New Zealand Operation Manual...
Whilst hot water outlets are open the set temperature may be lowered. However they cannot then be raised above 43°C. In addition transfer of 'Priority' between NOTE controllers is not possible. These are safety features. Rinnai New Zealand Operation Manual...
Be careful not to overfill the bath, an average bath volume is 160 litres. It is recommended that when filling a bath for the first time you should: • Remain by the bath during the filling process. • Use a low bath fill volume such as 100 litres or less. Rinnai New Zealand Operation Manual...
Universal and Deluxe Controllers can be combined and will function as described in other sections of this manual. Refer to the table on page 6 to confirm the maximum number and combination of controllers that can be fitted to your Water Heater model. Rinnai New Zealand Operation Manual...
In all cases, you may be able to clear the Error Code simply by turning the hot water tap OFF, then ON again. If this does not clear the Error Code, try pushing the On/Off button OFF, then ON again. If the Error Code still remains, contact Rinnai for advice.
Extended Warranty for Rinnai Infinity Heat Exchanger The warranty on heat exchangers in Rinnai infinity in domestic use is 10 years pro rata (i.e. in the 4 year, 70% of the value of the part is covered and 40% in the 7 year).
AS/NZS3000, AS/NZS3500 and NZS5261, local regulations and municipal building codes. All Rinnai water heaters must only be installed, commissioned and removed by persons Authorised by local regulations to do so. All Rinnai water heaters must only be serviced and repaired by a Rinnai approved service technician.
COMMON STACK DISCHARGE ......................25 TUNDISH DRAIN LINES ........................... 25 AREAS SUBJECT TO FREEZING ......................25 WATER CONTROLLER INSTALLATION..............26 RINNAI WATER CONTROLLERS ......................26 POSITIONING OF WATER CONTROLLERS ................... 26 WATER CONTROLLER CABLES ......................26 FITTING THE ‘UNIVERSAL’ WATER CONTROL (MC-91-2A) ..............26 OPTIONAL PROGRAMMING FOR THE ‘UNIVERSAL’...
This appliance must not be used as a domestic spa or swimming pool heater. This appliance MUST be used with the Rinnai Infinity flueing system only. The use of a non Rinnai flueing system may result in a dangerous situation and violates regulations.
‘Maximum’ rated water supply pressures in Table 1 are exceeded. To achieve the rated flow, the ‘Minimum’ water supply pressures in Table 1 must be supplied. The water heaters will operate at lower pressures but will not achieve the rated flow. Contact Rinnai for ‘gravity fed’ or ‘low pressure’ installations.
AS/ NZ3500.4 a Temperature Limiting Device (TLD), such as a Tempering Valve may be required even if the appliance is set to 55º C or less. For these types of applications contact Rinnai. REQUIREMENTS FOR INFINITIES INSTALLED WITHOUT CONTROLLERS ENSUITE...
*Contact Rinnai for exemptions for the above clearances which may have been granted since printing of this document. MULTIPLE INSTALLATIONS OF EXTERNAL MODELS Dimension ‘h’...
Hot: Length Hot Water outlet (from base) Condensate Connection Length (from base) Gas: Fitting Diameter Cold: Fitting Diameter Hot: Fitting Diameter Condensate: Fitting Diameter * Please note that this measurement is to the left of the centre line. Rinnai New Zealand Installation Manual...
For this reason copper tube and fittings MUST NOT be used as it will corrode. Instead, Rinnai recommend plastic pipes and fittings such as Unplasticised Polyvinyl Chloride (UPVC) or Polyethylene (PE) which is commonly used for irrigation piping.
300 mm in length. It shall discharge into a tundish through an air gap of not less than 75 mm and not more than 150 mm measured from the outlet of the drain pipe to the rim of the tundish. Rinnai New Zealand Installation Manual...
Water controls operate at extra low voltage (12 Volts DC) which is supplied from the water heater. Controllers come supplied with 15 m of electrical cable. The appliance end of the controller cables are fitted with spade terminals. Extension cabling is available from Rinnai. Alternatively, a two core sheathed (double insulated) flex with minimum cross- sectional area of 0.5 mm²...
Using the wall mounting bracket as a template mark and drill 3 holes. Locate the cable access hole as shown in Fig. 1. Fix the mounting bracket to the wall using the approriate fixings. Run the control cable through the hole in the wall. Fig.1 Rinnai New Zealand Installation Manual...
Remove the protective plastic film from the controller face as shown in Fig. 4. Replace the face plate and close the flip panel. Remote Control Cable Film Connector Screw Face Plate Face Plate Fig. 2 Fig. 3 Fig. 4 Rinnai New Zealand Installation Manual...
Extension cables are available from Rinnai. Alternatively, two core sheathed (double insulated) flex with minimum cross sectional area of 0.5mm² may be used. Cable lengths must not exceed 20 metres.
A commissioning check list is provided to enable the installer to step through the correct commissioning procedure when installing a Rinnai continuous flow water heater. The check list can also assist the installer to identify potential installation errors that may prevent the appliance from operating correctly.
If flue length exceeds 2m, dip-switch 1 of SW1 is to be switched to the 'OFF' position as shown. PLEASE NOTE: That warranty may be voided and a service charge may be incurred as a result of Rinnai staff attending to a problem related to installation. Rinnai New Zealand...
Recess Box: When installing an Rinnai continuous flow hot water heater in a new home or renovation, it is a great idea to allow for a recess box to be included at the construction stage. These boxes allow you to literally recess the appliance into the cavity of the wall saving precious space.