HARBOR POINT WALL SPLIT DUCTLESS SYSTEMS
Remove indoor and outdoor units from
the carton/box. Indoor unit carton con-
tains, remote control and batteries, en-
sure these are kept in a safe place during
installation.
8"
from wall
minimum
Ensure no obstacles to airflow are directly
in front of the unit, for a minimum of 12 ft
for 9,000/12,000 Btuh units and 16 ft for
18,000/24,000 Btuh units.
INDOOR UNIT INSTALLATION
CAUTION
!
Follow Instructions, failure to follow
instructions may cause possible mal-
function and void any warranty.
CEILING
4ft from floor (minimum)
6ft plus from floor (optimum)
FLOOR
!
Locate area to install indoor unit the
unit should be located a minimum of 6 ft.
from the floor and 6" from the ceiling.
Choose an area where the wall is plumb
and determine how to best to run the unit
interconnects.
6" from ceiling m
6" from ceiling minimum
Do not install the Indoor unit units in areas
exposed to high humidity (Relative Hu-
midity of 80% or more), direct sunlight and
direct heat from stoves or other devices.
6
8"
from wall
minimum