Refrigerant Line Set Piping; Indoor Unit - Harbor Point HF-25GW Installation, Operation And Maintanance Manual

Wall split ductless cooling only and heat pump systems
Table of Contents

Advertisement

HARBOR POINT WALL SPLIT DUCTLESS SYSTEMS

Refrigerant Line Set Piping

Interconnecting
line
outdoor unit and the indoor unit, must have
both refrigerant lines
expansion device is located in the outdoor
unit.
Gently bend the line set stubs from the
in- door unit to the desired location.
Using 2 x 10"/12" Crescent wrenches
remove the flare nuts from the indoor
unit line stubs.
The indoor unit is filled with a dry
gas, check for release of this to ensure
that no leaks are present. Use a small
amount of vacuum pump oil on the male
flare threads to ease installation.
remove line
set cover

Indoor Unit

set
between
the
insulated
as
the
Outdoor
Unit
Connect the line set to the stubs.
Using the 2 wrenches, 1 on the male
and 1 on the female tighten the flare
nuts. Run the line set to the outdoor
unit, avoid tight bends and kinking
the lines.
If line set length is in excess of that
re- quired, cut line set and re-flare or
coil ex- cess vertically to facilitate oil
return to the compressor.
Service port
9,000/12,000 shown
18,000/24,000 has additional
Install the line set on the
indoor unit stubs.
10
Gas line service valve
Line set connections
under the GRAY
caps.
Liquid line service valve
liquid line port