Operation Helpful Hints; Cleaning And Sanitizing Procedures - Ugolini ARCTIC COMPACT Service Manual

Juicer
Table of Contents

Advertisement

ARCTIC COMPACT & DELUXE

5. 2 OPERATION HELPFUL HINTS

1 The length of time for cooling down the product is governed
by many variables, such as ambient temperature and beverage
initial temperature.
2 To shorten product cooling down time and increase produc-
tivity, it is advisable to pre-chill the product to be used in the
dispenser.
3 To shorten product cooling down time and increase produc-
tivity, the bowl should be refilled after the product level drops
lower than half and at the start of each day.
4 The dispenser must be able to emit heat.
In case it seems excessive, check that no heating source is
close to the unit and air flow through the slotted panels is not
obstructed by wall or boxes. Allow at least 15 cm (6") of free
clearance all around the dispenser.
In any case if the product in the bowls is cold the unit is running
properly.
5 How to reset beverage temperature:to reset beverage tem-
perature please apply to a technician.
The proper temperature is preset at the factory.
5. 3 CLEANING AND SANITIZING
PROCEDURES
Cleaning and sanitizing of the dispenser are recommended to
guarantee the conservation of the best product taste and the
highest unit efficiency. This section is a procedural guideline
only and is subject to the requirements of the local Health
Authorities.
Prior to the disassembly and cleaning, the machine must be
emptied of product.
5. 3. 1 DISASSEMBLY
ATTENTION
Before any disassembly and/or cleaning procedure make
sure that the dispenser is disconnected from its power
source by unplugging it or switching off the 2-pole wall
breaker.
1 Remove cover from the bowl.
2 Remove the empty bowl by pulling lever (1) and lifting its
front side (faucet side) up and off bowl gasket (see figure 2).
3 Remove the bowl gasket.
4 Remove the pump impeller from its location.
5 Pinch tube faucet: push the dispensing handle (1) and
figure 2
take the pinch tube off from its seat (2) (see figure 3).
6 Gravity faucet: extract the piston and then remove the
dispensing handle (see figure 4).
7 Slide drip tray out and empty it.
5. 3. 2 CLEANING
IMPORTANT
Do not attempt to wash any machine components in a
dishwasher.
ATTENTION
Before any disassembly and/or cleaning procedure make
sure that the dispenser is disconnected from its power
source.
1 Prepare at least two gallons of a mild cleaning solution of
warm (45-60 °C 120-140 °F) potable water and dishwashing
detergent. Do not use abrasive detergent.
Important: if present, follow label directions, as too strong a
solution can cause parts damage, while too mild a solution will
12