General Troubleshooting Guide (Continued)
PROBLEM
5. The upper platen will not stay
in the raised position.
6. The product is under-cooked,
overcooked, or cooking
unevenly.
7. The control is displaying a
fault.

Control Board and Terminal Cleaning

Under several occasions we have found controls and
thermocouples replaced when faults such as TOO
COOL, TOO HOT, and thermocouple faults are
displayed. We have found that using contact cleaner
on the terminals, connectors, and board surfaces will
clear these problems. If contact cleaner is used,
please be sure all components are DRY before
restoring power to the unit.
This option is suggested prior to component
replacement.
Models QS12/QS24
PROBABLE CAUSE
a. Defective gas filled cylinder(s).
a. The release material sheet is
worn.
b. The cooking time is incorrect.
c. The temperature setting is
incorrect.
d. The gap setting is incorrect.
e. The heater is not heating.
f. The upper platen surface has
carbon build-up.
g. The incorrect item is selected.
h. The platen is not level.
a. Refer to the "fault screens",
page 10.
23
REMEDY
a. Replace the cylinder(s).
a. Replace the release material
sheet.
b. Adjust the cook time
accordingly.
c. Adjust the temperature setting.
d. Adjust the gap.
e. Refer to Problem #2.
f. Closing procedures must be
followed to remove carbon
build-up.
g. Select the proper item.
h. Refer to the Leveling
Procedures on page 16.
a. Clear the fault. If action is
ineffective, evaluate the
thermocouple connections and
the relay board.