Maintenance Menu

The Maintenance Menu provides five screens to allow
managers and service technicians to monitor grill
performance.
To enter the Maintenance Menu while any item is
displayed, press and hold the MENU keypad for
approximately 5 seconds and release. The following
screen will appear on the display:
CODE 0000
Press the TIME keypad until the first digit is "5".
Example: CODE 5000.
Press the TEMP keypad until the next digit is "3".
Example: CODE 5300.
Press the UP Arrow until the next digit is "7".
Example: CODE 5370.
Press the DOWN Arrow until the last digit is "6".
Example: CODE 5376.
Press the MENU keypad to accept the access code.
The following screen will appear on the display:
Note: If an incorrect code is entered, the display will
return to the COOKING screens.
CALIBRAT
Step 1
Press the MENU keypad to enter the calibrate mode
and the following message will appear on the screen.
U F X X X F
Note: Calibration is allowed only when the Item 1
temperatures are within 50_F (28_C) of the set point.
There are three lower heating elements in each cook
zone and three heating elements in the upper platen
(if
applicable).
The
calibrating
calibration of each independent heating element.
Models QS12/QS24
Calibrating verifies proper temperatures of heating
elements.
Note: A
calibration.
Step 2
Place the pyrometer disc on the upper front heating
element of the grill. Using the arrow keypads, enter the
temperature shown on the pyrometer for the upper
front heating element.
Note: The indicating lights should be lit when
calibration adjustments are made.
Step 3
Press the MENU keypad to display the calibration
screen for the upper middle heating element. Place the
pyrometer on the upper middle heating element. Using
the arrow keypad, enter the temperature reflected on
the pyrometer for the upper middle heating element.
Note: Calibration is allowed only when the Item 1
temperatures are within 50_F (28_C) of the set point.
Step 4
Repeat this procedure for the remaining upper rear
and lower elements. When the last zone has been
calibrated, press the MENU keypad to return to the
CALIBRAT screen.
Step 5
Press the UP arrow to display the SCALE message.
Note: The
maintenance screen. All other maintenance
screens
allow
functions are accessible through the CALIBRAT
screen.
11
calibrated pyrometer must be used for
Figure 2
CALIBRAT
screen
Controls and Systems