4.30 Fluorescent Lamp

4
4.30 Fluorescent Lamp
This system uses LCD modules from the following suppliers. The procedure for replacing
the fluorescent lamp is different for each LCD module. Refer to the appropriate procedure.
Type
15.4-inch (WXGA)
15.4-inch (WSXGA+)
NOTE: - When working with a LCD module, always use a flat, grounded table.
- Handle the backlight unit in the environment without dust, such as on the clean
bench. Keep the worktable free from any screws or other material that may
scratch the LCD surface.
- Use an anti-static or protective sheet.
- When replacing the FL unit, cover with a finger protector or similar to prevent
soiling or scratching the LCD panel.
- Be careful when handling the lamp. Excessive force may break the lamp.
- Be careful not to soil or deform the lamp reflector.
- Make sure that the power of the LCD module is turned off before connecting or
disconnecting cables and connectors.
TECRA A9/TECRA S5/TECRA P5/Satellite Pro S200 Maintenance Manual (960-633) [CONFIDENTIAL] 4-95
Part No.
Supplier
G33C0003F110
SAMSUNG
G33C0003Z110
4 Replacement Procedure
Section
4.30.1
4.30.2