Specifications Of Electrical Parts; Compact 4-Way Cassette Type; Concealed Duct Type; Ceiling Type - Toshiba RAV-SM404MUT-E Service Manual

Split type
Hide thumbs Also See for RAV-SM404MUT-E:
Table of Contents

Advertisement

4. SPECIFICATIONS OF ELECTRICAL PARTS

4-1. Compact 4-way Cassette Type

No.
Parts name
1
Fan motor (for indoor)
2
Thermo. sensor (TA-sensor)
3
Heat exchanger sensor (TCJ-sensor)
4
Heat exchanger sensor (TC-sensor)
5
Float switch
6
Drain pump motor

4-2. Concealed Duct Type

No.
Parts name
1
Fan motor (SM804BT)
Fan motor
2
(SM564BT/SM1104BT/SM1404BT)
3
Thermo. sensor (TA-sensor)
4
Heat exchanger sensor (TCJ-sensor)
5
Heat exchanger sensor (TC-sensor)
6
Float switch
7
Drain pump motor
8
Reactor

4-3. Ceiling Type

No.
Parts name
1
Fan motor (SM564CT)
2
Fan motor (SM804CT)
3
Fan motor (SM1104CT/SM1404CT)
4
Thermo. sensor (TA-sensor)
5
Heat exchanger sensor (TCJ-sensor)
6
Heat exchanger sensor (TC-sensor)
7
Louver motor
8
Reactor
Type
SWF-230-60-1R
155 mm
Ø6 mm, 1200 mm
Ø6 mm, 1200 mm
FS-0218-102
ADP-1409
Type
ICF-280-120-1C
ICF-280-120-2C
618 mm
Ø6 mm, 1200 mm
Ø6 mm, 1200 mm
FS-0218-102
ADP-1409
CH-43-2Z-T
Type
SWF-280-60-1R
SWF-280-60-2R
SWF-280-120-2R
155 mm
Ø6 mm, 1200 mm
Ø6 mm, 1200 mm
MP24Z2N
CH-43-2Z-T
– 23 –
Specifications
Output (Rated) 60 W, 220–240 V
10 kΩ at 25°C
10 kΩ at 25°C
10 kΩ at 25°C
Specifications
Output (Rated) 120 W, 220–240 V
Output (Rated) 120 W, 220–240 V
10 kΩ at 25°C
10 kΩ at 25°C
10 kΩ at 25°C
10 mH, 1 A
Specifications
Output (Rated) 60 W, 220–240 V
Output (Rated) 60 W, 220–240 V
Output (Rated) 120 W, 220–240 V
10 kΩ at 25°C
10 kΩ at 25°C
10 kΩ at 25°C
DC 15V
10 mH, 1 A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents