Toshiba RAV-SM404MUT-E Service Manual page 34

Split type
Hide thumbs Also See for RAV-SM404MUT-E:
Table of Contents

Advertisement

No.
Item
13
(Continued)
For ceiling type only
Outline of specifications
1) Louver position setup
• When the louver position is changed, the position
moves necessarily to downward discharge position
once to return to the set position.
• The louver position can be set up in the following
operation range.
In cooling/dry operation
• In group operation, the louver positions can be set up
collectively or individually.
2) Swing setup
• The swinging position can be moved in the following
operation range.
All modes
• In group operation, the swinging positions can be set
up collectively or individually.
3) When the unit stops or when a warning is output, the
louver automatically moves downward.
4) While the heating operation is ready or self cleaning,
the louver automatically moves upward.
– 34 –
In heating/fan operation
Remarks
Alarm :
A check code is
displayed on the
remote controller, and
the indoor unit stops.
(Excluding [F08] and
[L31])