Konica Minolta FK-101 Service Manual page 52

Konica fk-101 mfp service manual
Table of Contents

Advertisement

HOME
Detailed Explanation
RCV signal detect mode
• Sets to "Time" when ninger can not be detected by the number.
Pause time
The pause time for one pause key (pause between digits)
Response waiting time
Refer to 3.2.2 T1 TIMER section.
DC-LOOP check
Checks the DC loop current before dialing.
When the current is zero, an error occurs. (T.80, an error code is not displayed.)
You can change the setting to be compliant to standards in other countries. In Japan, set this
parameter to OFF.
Busy tone detection and No. of busy tones
Parameter
RCV signal detect mode
RCV signal detect time
Pause time
Response waiting time
DC-LOOP check
Busy tone detection
No. of busy tones
1300 Hz detection
Pseudo RBT send level
Pseudo RBT cadence
min.RING OFF time
Toot
Toot
Set Value
Number / time
0 to 15[second]
(in steps of 1 second)
1 to 7[second]
(in steps of 1 second)
35 to 115[second]
ON / OFF
ON / OFF
0 to 15[times]
(Zero time equals to no detection.)
ON / OFF
-10 to -15[dBm]
(in steps of 1dB)
None, Japan, USA, UK and German
100 to 1,000[ms]
Toot
When the number of tones is set to
three, judged to be busy here.
3-12
Factory-shipped
Reference
Default Setting
Number
Yes
6[sec]
1[sec]
Yes
55[sec]
Yes
OFF
Yes
ON
Yes
2
Yes
ON
-10[dBm]
Japan
200[ms]