Gas adjustment (Conversion to LPG)

All
work
registered engineer.
IMPORTANT: Always isolate the hob from the electricity supply
before changing the injectors and/or adjusting the minimum
flow of the burners.
Kind of gas
Natural
In:72/Out:95
L.P.G.
In:46/Out:66
Butane
Propane
must
be
o Remove the pan-stands, burners and
flame spreaders (A).
o Unscrew the injector (B) and replace it
with the stipulated injector for the new gas
supply (see table below).
GENERAL INJECTORS TABLE
Nozzle
Burners
mm/100
Wok (4.20 kW)
135
Wok (3.80 kW)
124
Wok (3.30 kW)
115
97
Semi-rapid
72
Auxiliary
Wok (4.20 kW)
98
Wok (3.80 kW)
91
Wok (3.30 kW)
85
65
Semi-rapid
50
Auxiliary
carried
out
by
Power (in watts)
Max.
4200
3800
3300
Rapid
3000
1750
1000
4200
3800
3300
Rapid
3000
1750
1000
a
GASSAFE
Min.
1850
1500
1500
750
440
300
1850
1500
1500
750
440
300
25