YASKAWA Lift Inverter L1000V Quick Start Manual page 49

Lift inverter series ac drive
Hide thumbs Also See for Lift Inverter L1000V:
Table of Contents

Advertisement

LED Display AL FLT
Output Phase
Loss
LF
Overcurrent
oC
Encoder
Communicatio
n Data Error
oFx53
Encoder Error
oFx54
Heatsink
Overheat
oH or oH1
Motor
Overload
oL1
Drive
Overload
oL2
DC
Overvoltage
ov
YASKAWA ELECTRIC YEG-TOEP-C710606-50A-1-0YaskawaACDrives-L1000VQuickStartGuide
Possible Cause
• Output cable is disconnected or the motor
winding is damaged.
• Drive output wires are loose.
• Motor is too small (less than 5% of drive
current).
• Short-circuit or ground fault on the drive
output side.
• The load is too heavy.
• The acceleration or deceleration ramps are
too short.
• Incorrect motor data or V/f pattern settings.
• The motor contactor was switched while
the drive was running.
• Encoder power supply voltage wrong.
• Wrong encoder type.
• Wrong wiring.
• Noise on the encoder signal.
• Bad wiring.
• Surrounding temperature is too high.
• The cooling fan has stopped.
• The heatsink is dirty.
• The airflow to the heatsink is restricted.
• The motor load is too heavy.
• Acceleration and deceleration cycle times
are too short.
• Value set for the motor rated current is
incorrect.
• The load is too heavy.
• The drive is too small.
• Too much torque at low speed.
• DC bus voltage rose too high.
• Braking transistor is too small
• Braking chopper or resistor is broken.
• Unstable motor control in OLV.
• Input voltage is too high.
8 Troubleshooting
Corrective Action
• Check the power supply.
• Make sure that all cables are properly con-
nected to the correct terminals.
• Check the output wiring and the motor for
short circuits or broken insulation. Replace
the broken parts.
• Check the machine for damages (gears,
etc.) and repair any broken parts.
• Make sure the brake fully opens.
• Check accel/decel settings in C1-
C2-
.
• Check V/f pattern settings in E1-
• Check the output contactor sequence.
• Check the encoder power supply setting on
the option card.
• Check the encoder wiring, especially the
serial signal wires.
• Check the encoder wiring and make sure
the encoder cable shield is properly
grounded.
• Check the surrounding temperature and
install cooling devices if necessary.
• Check the drive cooling fan.
• Clean the heatsink.
• Check the airflow around the heatsink.
• Check the elevator mechanics.
• Check the sequence.
• Check the rated current setting.
• Check the load.
• Make sure that the drive is big enough to
handle the load.
• The overload capability is reduced at low
speeds. Reduce the load or increase the
drive size.
• Make sure the braking resistor and braking
chopper are working correctly.
• Check motor parameter settings and adjust
torque and slip compensation as needed.
• Make sure that the power supply voltage
meets the drives specifications.
and
.
47

Advertisement

Table of Contents
loading

Table of Contents