Check the followinglistto be sure a service call is really necessary. A quick reference
of this manual may prevent an unneeded service call.
If grill or surface burner fails to light:
• check 10be sure unitis properlyconnectedto powersupply.
• check for a blowncircuitfuse or a trippedmain circuitbreaker.
• check to be sure burnerportsor ignitionportsare not clogged.
• checkto be sure igniterisclicking. If igniterdoesn'tclick,turncontrolknobOff and
clean iginitor. (See p. 46.)
s check to be sure appliance regulator is set for correct fuel. (See installation
instructions.)
• checkto be sure inletpressureis adequate. (Call gas company.)
if the flame is uneven:
• burner ports may be clogged.
• flame settingmay need to be adjusted. (See p. 13.)
If grill or surface burner flame lifts off the ports:
• shutteronthe mixertube needsto be closeduntilflamesettleson the burnerports.
(See pp. 12-13.)
If grill or surface burner flame is yellow in color:
• shutteron the mixertube needsto be openeduntilyellow disappears. (See pp. 12-
13)
If nothing on the range operates:
• checkfor a blown circuitfuse or a tripped main circuitbreaker.
• check if range is properlyconnectedto electric circuitin house.
If ventilation fan does not operate but everything else on the range
does:
• check behind lower access panel if power cord to blower assembly has been
disconnected.
If ventilation system is not capturing smoke efficiently:
• check on crossventilation in room or make up air.
• excessive amount of smoke is being created; check instructions for grilling,
trimming meats. (See pp. 18-20.)
s outside wall cap may be trapped shut.
• range may be improperly installed; check ducting information. (See p. 9.)
• air filter may be improperly installed (See p. 10.)