3.10 Scanning Image Defect Troubleshooting
3.10.1 Image defect examples
3.10.2 Troubleshooting image defect
■ Light on the page (Error code BB, etc)
Step
White level data malfunction
1
2
Document scanner unit failure
3
Main PCB failure
Light (2-96)
Faulty registration (2-97)
Completely blank
Vertical streaks (2-98)
(2-98)
User Check
• Check whether the setting of the contrast does not become light.
• Clean the document table glass or ADF glass.
• Clean the CIS glass of the ADF.
Cause
Fig. 2-14
Perform the acquisition of white level data.
("Function code
Replace the document scanner unit.
Replace the main PCB ASSY.
2-96
Dark (2-97)
White vertical
streaks (2-98)
Remedy
55")
Confidential