6.1.3

K-PWA-DLM-320

It is feasible to update the firmware automatically by connecting the download jig to the ADF control PC
board and turning the power of the equipment ON.
< Procedure >
(1)
Turning OFF the power of the equipment and take off the ADF rear cover.
(2)
Connect the download jig with the connector (CN81) on the PC board.
(3)
While pressing [0] and [8] simultaneously, turn ON the power. (rewriting data starts)
(4)
During the data is rewritten, the LED on the download jig lights. When the data rewriting is
completed, the LED blinks slowly (at an interval of 0.8 sec.). If the LED blinks fast (at an interval
of 0.1 sec.), the rewriting has been failed.
(5)
Turn OFF the power of the equipment and remove the download jig.
(6)
Install the ADF rear cover.
* If rewriting data is failed, turn OFF the power and repeat the procedure.
Note:
Be sure to print out the list to confirm the firmware version for the ADF.
P.2-11 "2.2.4 List Print Mode (9S)"
e-STUDIO181/211
FIRMWARE UPDATING
Connector
Fig. 6-12
© 2009 TOSHIBA TEC CORPORATION All rights reserved