3.7.3

Scan motor (CIS unit drive belt-2)

When installing the scan motor and CIS unit drive belt-2, adjust the tension of the CIS unit drive belt-2
with the belt tension jig.
<Procedure>
(1)
Temporarily fix screws A and B.
(2)
Hook the belt tension jig on the motor
bracket and frame.
(3)
Tighten screws A and B where the scan motor pulled by the belt tension jig stops.
© 2009 TOSHIBA TEC CORPORATION All rights reserved
Fig. 3-26
Scan motor
Fig. 3-27