Notes:
The digit after the hyphen in "Code" of the following table is a sub code.
In "RAM", the SRAM of the board in which the data of each code is stored is indicated. "M"
and "SYS" stands for the MAIN board.
Classifi
Code
cation
200
Develop
Automatic adjustment of
er
auto-toner sensor
(Fuser heater ON)
201
Develop
Correction of auto-toner
er
sensor
(Fuser heater ON)
205
Develop
Developer bias DC output
er
adjustment
210
Charger Main charger grid bias
output adjustment
220
Transfer Transfer transformer DC
output adjustment (H)
221
Transfer Transfer transformer DC
output adjustment (C)
222
Transfer Transfer transformer DC
output adjustment (L)
233
Separati
Separation transformer DC
on
output adjustment (H)
234
Separati
Separation transformer DC
on
output adjustment (C)
235
Separati
Separation transformer DC
on
output adjustment (L)
247
Develop
Relative humidity latest
er
value
248
Develop
Drum temperature latest
er
value
270
Develop
Temperature latest value
er
280
Process Forced performing of idling
for toner recycle
286
Laser
Laser power adjustment
© 2009 TOSHIBA TEC CORPORATION All rights reserved
Adjustment mode (05)
Default
Funct
<Accept
Items
ion
value>
ALL
ALL
<0-255>
ALL
<0-255>
ALL
<0-255>
ALL
<0-255>
ALL
<0-255>
ALL
<0-255>
ALL
<0-255>
ALL
<0-255>
ALL
<0-255>
ALL
<0-100>
ALL
<0-100>
ALL
<0-50>
ALL
ALL
<0-255>
2 - 21
RAM
Contents
able
-
-
As the value increases,
the sensor output
increases
correspondingly.
The value starts
changing approx. 2
minutes after this
adjustment was started
and is automatically set
in the range of 2.35 to
2.45 V.
*
Selection is disable
when developer unit
is not installed. (Ch.
3.1)
141
M
Corrects the control
value of the auto-toner
sensor setup in 05-200.
*
Selection is disable
when developer unit
is not installed.
135
M
As the value increases,
the transformer output
increases
75
M
correspondingly.
Remove the developer
117
M
unit and install the
adjustment jig to make
128
M
adjustment.
(Ch. 3.6)
101
M
65
M
65
M
47
M
50
M
Displaying of the relative
humidity latest value.
25
M
Displaying of the drum
temperature latest value.
25
M
Displaying of the
temperature latest value.
-
M
Perfom this adjustment
before the replacement
of the developer
material.(The toner is
forcibly removed from
the cleaner.)
60
M
When the value
increases, the laser
output increases
correspondingly.
ERROR CODE AND SELF-DIAGNOSTIC MODE
2
Proce
dure
17
3
3
3
3
3
3
3
3
3
2
2
2
6
3
e-STUDIO181/211