Command
Function (3Com/US Robotics)
S$
Display the list of S-register settings
Sr=n
Set S-Register "r" to "n"
Sr?
Display the value of S-Register "r"
V0
Display result codes in numeric form
V1
Display result codes in verbose form (words)
X0
Report basic call progress result codes, i.e., OK, CONNECT, RING, NO CARRIER, (also, for busy, if
enabled, and dial tone not detected), NO ANSWER and ERROR
X1
Report basic call progress result codes and the connect rates—OK, CONNECT, RING, NO CARRIER
(also, for busy, if enabled, and dial tone not detected), NO ANSWER, CONNECT XXXX and ERROR
X2
Report basic call progress result codes and the connect rates i.e., OK, CONNECT, RING, NO CARRIER
(also, for busy, if enabled), NO DIAL TONE, NO ANSWER, CONNECT XXXX and ERROR
X3
Report basic call progress result codes and connection rate i.e., OK, CONNECT, RING, NO CARRIER, NO
ANSWER, CONNECT XXXX, BUSY and ERROR
X4
Report all call progress result codes and connection rate i.e., OK, CONNECT, RING, NO CARRIER, NO
ANSWER, CONNECT XXXX, BUSY, NO DIAL TONE and ERROR
Y0
On the next reset, use &W0 settings
Y1
On the next reset, use &W1 settings
Y2
On the next reset use, &F0 settings
Y3
On the next reset, use &F1 settings
Y4
On the next reset, use &F2 settings
Z0
Reset the modem according to the settings of ATY
Z1
Reset the modem and use &W0 settings
Z2
Reset the modem and use &W1 settings
Z3
Reset the modem using &F0 settings and load factory default profile 1
Z4
Reset the modem using &F1 settings and load factory default profile 0
Z5
Reset the modem using &F2 settings and load factory default profile 2
$
Display the list of AT commands
&$
Display the list of ampersand commands
&A0
Disable data compression result codes
&A1
Enable data compression result codes
&A2
Enable modulation result codes
&A3
Enable data compression result codes and add V.42bis and MNP 5 protocol indicators
&B0
Use a floating DTE speed
&B1
Use a fixed DTE speed
&B2
Use a fixed DTE speed when using data compression
&C0
Carrier detect is always on
&C1
Carrier detect is controlled by the modem.
&D0
Ignore DTR
&D1
Use online command mode
&D2
DTE controls DTR
&D3
DTE controls DTR and reset
&F0
Set the factory profile that uses hardware (RTS/CTS) flow control (this is the active profile when the modem
is shipped)
&F1
Set the factory profile that uses hardware (RTS/CTS) flow control
&F2
Set the factory profile that uses software (XON/XOFF) flow control
&G0
No guard tone
&G1
Use 550 Hz guard tone
&G2
Use 1800 Hz guard tone
&H0
Flow control for transmitted data - Disable flow control