8. Alarm messages

8 Alarm messages
Faults
In the event of a fault, the display may show the following messages. Contact your fitter.
Message
Igniter fault
Ionization error
BURNER FAILURE
Gas valve defective
No gas or presence of air in the pipe
Incorrect positioning of the electrode
Ignition cable or electrode connector
CVI8 FAILURE
defective
Internal safety control box fault
Electrical impulse fault on the gas valve
control
Poor contact between the safety control
CVI9 FAILURE
box and the valve
Gas valve control in the safety control
box is defective
CVI10-22 FAILURE
Internal safety control box fault
Communication error between
CVI COM.FAULT
DIEMATIC and safety control box
MANOMETRE FAIL
Fault on the water pressure sensor
ROOM S.A FAIL.
ROOM S.B FAIL.
ROOM S.C FAIL.
OUTL S.B FAIL.
OUTL S.C FAIL.
Fault in the corresponding sensor
OUTSI. S.FAIL.
SOLAR S. FAIL
FAN FAILURE
SWIM.P. S.FAIL
The hot water storage tank reheating
ST.TANK S.FAIL
operation is no longer assured
BOILER S.FAIL.
Boiler sensor defective
DHW S. FAILURE
Domestic hot water sensor defective
TA-S SHORT-CIR
There is a short circuit in the TAS
TA-S DISCONNEC
The TAS is in open circuit
TA-S FAILURE
Internal problem
14
Probable causes
Reset the safety control box. Contact your fitter.
Switch off and reignite the boiler to restart heating for a period of
message continues to be displayed.) Contact your fitter.
Contact your fitter.
DTG 1300 Eco.NOx Plus / V130
Solution
72
10/11/2009 - 300002784-001-F