2. Important recommendations

2.1 Aeration

2.1.1

Chimney versions

Do not obstruct the air inlets in the room (even partially).
France: the cross section of the aeration vent, which is compulsory
in the boiler room in which the boiler is installed, must comply with the
DTU 61.1 (P 45 204) standard and, in particular, with the instruction
on boiler room layout (Book 1764 April 1982).
Belgium:the cross-section of the aeration vents, which are
compulsory in the room in which the boiler is installed, must comply
with the NBN D51-003 standard.
2.1.2

Forced flue versions

It is not necessary to provide ventilation of the premises in which the
boiler is installed. Ventilation is required if a mechanical connection
to the gas exists.

2.2 Maintenance

- The servicing and cleaning of the boiler and the sweeping of the
flue gas pipe and the bleed pot must be done at least once a year
by a qualified professional. We recommend taking out a
maintenance contract.

2.3 Adapting to another gas type

Belgium:
The operations required to switch from one gas to another must be
carried out by a SERV'elite technician.
Other countries:
The operations required to switch from one gas to another must be
carried out by your fitter.
4
Germany: the cross section of the ventiliation vents, which are
compulsory in the room in which the boiler is installed, must comply
with the VDI 2050 form 1 standard and with other prevailing
regulations.
Other countries: the cross section of the aeration inlet, which is
compulsory in the premises in which the boiler is installed, must
comply with the standards in force in the country.
- Regularly check the level of water in the system and top up if
required, taking care that cold water is not added suddenly into the
boiler when it is hot. If this operation is repeated several times per
season, locate the leak and repair it.
Do not drain the installation, except in cases of absolute
necessity. For example: Several months' absence with the
risk of ice in the building.