Siemens Building Technologies
Fire Safety & Security Products
ALARM MENU
TAMPER ALARM
ALARM 1
ALARM 2
ALARM 3
ALARM 4-7
GLOBAL ALARM SETTINGS
Fig. 25
The ALARM menu
1
) Each alarm can have up to 24 characters of text assigned to it. If blank, the
whole line is highlighted, press "Set" to add characters.
ALARM CONFIGURATION
ALARM ..... (Tamper/1-3/4-7)
ENABLED .. YES/NO
CONTACT .. N/C / N/O
VIDEO BLANKING ... YES/NO
RELAY....... NONE/MOMENTARY/LATCHED
(Set Name)
CLEAR NAME
COPY
PASTE
BACK
ALARMS 4-7
ALARM 4
BACK
ALARM 5
ALARM 6
ALARM 7
BACK
GLOBAL SETTINGS
LOCAL REPORT ..... YES/NO
REMOTE REPORT .. YES/NO
ALARM RESUME.... OFF/HOME/TOUR1-4/
TIME PERIOD ........ 5SECS-30MINS
HELP
BACK
1
PATTERN1-4/RANDOM
08.2006