The Soft Limits And Sectors Menu - Siemens Solaris CCDS1415-ST Configuration Manual

Solaris
Table of Contents

Advertisement

11.1.5 The Soft Limits and Sectors menu

50
Siemens Building Technologies
Fire Safety & Security Products
Soft limits
The Soft Limits menu will allow you to set up and remove programmable soft limits
to the vertical travel of the camera.
Once the upper and lower limits are set, the camera will not view the areas above
or below those limits.
Sectors
The Solaris™ Dome's horizontal movement is divided into 16 sectors that can be
individually identified with a name. The Sectors item will allow you to configure the
names of the sectors.
When the sector function is activated (in the OSD menu, see Section 11.1.7), the
sector name is displayed on screen whenever the camera is looking into that
sector. The purpose of this is to provide the operator with help in orientation. The
Edit Sector menu allows you to edit the sector name.
For example: North >> East >> South >> West
LIMITS AND SECTORS
SET UPPER SOFT LIMIT
SET LOWER SOFT LIMIT
CLEAR SOFT LIMIT
SECTORS
Fig. 24
The SOFT LIMITS AND SECTORS menu
1
) Press 'Set' to delete the current soft limit settings.
2
) Use the joystick to tilt to the desired position. Select store to save the limit or
abort to exit without saving.
3
) Use the joystick to tilt to the desired position. Select store to save the limit or
abort to exit without saving.
4
) Each sector can have up to 24 characters of text assigned to it. If blank, the
whole line is highlighted, press 'Set' to add characters.
STORE UPPER SOFT LIMIT²
STORE
ABORT
STORE LOWER SOFT LIMIT³
STORE
1
ABORT
BACK
SECTOR MENU
SECTOR NUMBER...1-
16
(Set Name)
CLEAR NAME
COPY
PASTE
HELP
BACK
4
08.2006

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Solaris ccds1415-dnSolaris ccds1415-dnx

Table of Contents