Advantech PCM-9362 Series User Manual page 64

3.5" biscuit with intel atom n450/d510, vga, lvds, 2 giga-lan, usb, sata, mini pcie and ssd
Table of Contents

Advertisement

Click the READ GPIO DATA button and the status of the GPIO pin will be dis-
played in (R/W) Result field.
Test Read Multiple Input Pin
Click the radio button- Multiple-Pins.
Key in the pin number from '0x01' to '0x0F' to read the value of the input pin.
The pin numbers are ordered bitwise, i.e. bit 0 stands for GPIO 0, bit 1 stands
for GPIO 1, etc. For example, if you want to read pin 0, 1, and 3, the pin num-
bers should be '0x0B'.
Click READ GPIO DATA button and the statuses of the GPIO pins will be dis-
played in (R/W) Result field.
Test Write Single Output Pin
Click the radio button- Single-Pin.
Key in the pin numbers you want to write. Pin numbers start from '0'.
Key in the value either '0' or '1' in (R/W) Result field to write the output pin you
chose above step.
Click the WRITE GPIO DATA button to write the GPIO output pin.
Test Write Multiple Output Pins
Click the radio button- Multiple-Pins.
Key in the pin number from '0x01' to '0x0F' to choose the multiple pin num-
bers to write the value of the output pin. The pin numbers are ordered bit-
wise, i.e. bit 0 stands for GPIO 0, bit 1 stands for GPIO 1, etc. For example, if
you want to write pin 0, 1, and 3, the pin numbers should be '0x0B'.
Key in the value in (R/W) Result field from '0x01' to '0x0F' to write the value
of the output pin. The pin numbers are ordered bitwise, i.e. bit 0 stands for
GPIO 0, bit 1 stands for GPIO 1, etc. For example, if you want to set pin 0
and 1 high, 3 to low, the pin number should be '0x0B/, and then you should
key in the value '0x0A' to write.
Click the WRITE GPIO DATA button to write the GPIO output pins.
2
I
C
When the application is executed, you can read or write a byte of data through I2C
devices. All data must be read or written in hexadecimal system.
Read a byte
Key in the slave device address in Slave address field.
Key in the register offset in Register Offset field.
Click the READ A BYTE button and then a byte of data from the device will
be shown on the Result field.
PCM-9362 User Manual
56

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pcm-9362nc-s6a1ePcm-9362n-s6a1ePcm-9362d-s6a1e

Table of Contents