1.3.3
Electrical Specification
1.3.3.1
Power supply Voltage
Voltage requirement with AT/ATX Power:
AT:
±5% or +12 V
+5 V
DC
ATX:
+12 V
±5%, +5 V Standby for ATX mode
DC
or
±5%, +5 V Standby for ATX mode (12 V is optional for LCD inverter and add
+5 V
DC
on card)
1.3.3.2
Power Supply Current
Supply Current (ATX)
- Typical in XP mode:
PCM-9362NC-S6A1E: 5 V : 2.31 A
PCM-9362N-S6A1E: 12 V : 0.87 A
PCM-9362D-S6A1E: 12 V : 0.91 A
- Max in HCT:
PCM-9362NC-S6A1E: 5 V : 2.36 A
PCM-9362N-S6A1E: 12 V : 1.01 A
PCM-9362D-S6A1E: 12 V : 1.17 A
1.3.3.3
RTC Battery
Typical Voltage : 3.0 V
Nomal discharge capacity : 210 mAh
1.4
Environmental Specification
1.4.0.1
Operating Humidity
Operating Humidity:10% ~ 90% Relative Humidity, non-condensing
1.4.0.2
Operating Temperature
Operating temperature: 0 ~ 60°C (32~140°F)
1.4.0.3
Storage Humidity
Standard products (0 ~ 60°C)
Relative Humidity: 95% @ 60°C
1.4.0.4
Storage Temperature
Standard products (0 ~ 60°C)
Storage temperature: -20~70°C
±5%
DC
5
PCM-9362 User Manual