36
en | Troubleshooting
9
Troubleshooting
9.1
Camera Operation
The following table is intended to help you identify the causes of malfunctions and correct
them when possible.
Malfunction
No image
transmission to
remote location.
No connection
established, no
image transmission.
F.01U.412.061 | 2.0 | 2011.08
Possible causes
Defective camera.
Faulty cable connections. Check all cables, plugs, contacts and
Incorrect cable
connections.
The unit's configuration.
Faulty installation.
Instruction Manual
EX65 Explosion-protected Camera
Solution
Connect a local monitor to the camera and
check the camera function.
connections.
Ensure that Video and Sync connections
are not reversed.
When using DC power ensure that polarity
is correct.
Check all configuration parameters.
Check all cables, plugs, contacts and
connections.
Bosch Security Systems, Inc.