Tools and Parts

Gather the required tools and parts before starting installation. Read
and follow the instructions provided with any tools listed here.
Tools needed
Drill
1¹⁄₄" (3.2 cm) drill bit
¹⁄₈" (3.2 mm) drill bit for pilot holes
Pencil
Wire stripper or utility knife
Tape measure or ruler
Caulking gun and weatherproof caulking compound
Flat-blade screwdriver
Phillips screwdriver
Saber or keyhole saw
Vent clamps
Metal snips
Compass or circle template
Parts supplied
Remove parts from package. Check that all parts are included.
2 - Metal filters
4 - 4.5 x 13 mm mounting screws
2 - 3.5 x 9.5 mm damper screws
6" (15.2 cm) transition with damper
4 - 5 x 45 mm screws
10 x 50 mm wall anchors
T10
®
Torx
®†
adapter
®
®
T20
Torx
adapter
Parts needed
Home power supply cable
½" (12.7 mm) UL listed or CSA approved strain relief
3 - UL listed wire connectors
For top vented installations:
6" (15.2 cm) round metal venting
1 - wall or roof cap
For non-vented (recirculating) installations:
Recirculating Kit W10490330 - See Assistance or Service
section to order.
6" (15.2 cm) round metal venting
For rear vented installations:
3¹⁄₄" x 10" (8.3 x 25.4 cm) round metal venting
1 - wall or roof cap
3¹⁄₄" x 10" (8.3 x 25.4 cm) damper/vent connector (see the
"Assistance or Service" section to order)
For cabinets with recessed bottoms:
2 - 2" (5.1 cm) wide filler strips. Length and thickness
determined by recess dimensions.
4 - flat-head wood screws or machine screws with washers
and nuts (to attach filler strips).
†®TORX, T10 and T20 are registered trademarks of Acument Intellectual Properties, LLC.
4

INSTALLATION REQUIREMENTS

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
It is the installer's responsibility to comply with installation
clearances specified on the model/serial rating plate. The
model/serial rating plate is located inside the range hood on
the left wall.
Range hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance. Consult the
cooktop/range manufacturer installation instructions before
making any cutouts.
This range hood is recommended for use with cooktop with a
maximum total rating of 65,000 BTUs or less.
Grounded electrical outlet is required. See "Electrical
Requirements" section.
The range hood is factory-set for vented installations. For
non-vented (recirculating) installations, the Recirculation Kit is
W10490330. Replacement Charcoal Filters Part Number is
W10272068. See the "Assistance or Service" section to
order.
All openings in ceiling and wall where range hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
Product Dimensions
12"
(3.0 cm)
(30.5 cm)
7¼"
(18.4 cm)
1¹⁄₁₆"
2"
(2.6 cm)
(5.1 cm)
9"
(22.9 cm)
13¹²⁄₁₆"
(35 cm)
29⁷⁄₈" (75.9 cm) - 30" (76.2 cm) model
35⁷⁄₈ (91.1 cm) - 36" (91.4 cm) model
1³⁄₁₆"
3" (7.6 cm) -
30" (76.2 cm) model
5³⁄₄" (14.6 cm) -
36" (91.4 cm) model
⁵⁄₈"
(1.6 cm)
19³⁄₄"
(50.2 cm)