12.ERROR CODES

12.1 Error Code Lists

When an error occurs, following error codes are displayed in the Information column 4) in the screen on
page 15).
(1) Error codes related to an inverter error
Error Code
Error Name
(HEX)
Outside
17(11H)
parameter range
Operation mode
18(12H)
error
19(13H)
Running
Parameter write
20(14H)
disable
22(16H)
No parameters
23(17H)
No options
24(18H)
Narrow error
Instruction code
26(1AH)
error
Running in
33(21H)
present mode
34(22H)
With STF
35(23H)
With STR
Operation mode
36(24H)
specified
37(25H)
Pr. 75 specified
Data outside the setting range was specified for the running frequency (running
speed), parameter write or the like.
The present operation mode is not allowed to perform. Change the operation modes.
The inverter is running.
Parameter write is inhibited.
There are no parameters or related parameters have not been set.
The preset option is not connected to the inverter.
There is no difference between analog value settings of Pr. 902 (Pr. 904) and Pr. 903 (Pr.
905).
A non-existing instruction code was sent to the inverter.
Mode change etc. cannot be made since the inverter is running in the present
operation mode.
Mode change etc. cannot be made since the forward rotation command is entered.
Mode change etc. cannot be made since the reverse rotation command is entered.
Cannot be executed in the present operation mode.
Since Pr. 75 is specified, inverter reset cannot be executed.