Mitsubishi Electric FR-V5NE-E Instruction Manual page 48

Vector inverter
Table of Contents

Advertisement

No.
Name
Sampling item
1)
Sampling time
2)
Trigger selection
3)
Trigger condition
4)
5)
Trigger terminal
Trigger timing
6)
Status panel
7)
Measurement start
8)
Monitor
9)
Alarm display
10)
Select the item to be sampled.
<Sampling item>
Refer to the Monitor List (Refer to page 34.)
Enter the sampling interval. (50 to 30000ms)
Choose the external or internal trigger.
External trigger ...... Data sampling starts after start of measurement.
Internal trigger ....... Depending on trigger condition and timing.
Alarm trigger .......... Alarm occurrence is used as a trigger.
Select whether sampling will be started on the leading edge or trailing edge of the trigger
terminal signal.
Select the trigger terminal from the following items.
STF, STR, RES, DI1, DI2, DI3, DI4, OH, D01, D02, D03, ABC
Choose the timing for trigger waiting.
Before ...... 10240 pieces of data before establishment of trigger are displayed.
During ...... 5120 pieces of data before establishment of trigger and 5120 pieces after
establishment are displayed.
After ......... 10240 pieces of data after establishment of trigger are displayed.
Shows the status during sampling.
Used to start measurement.
Used to monitor the measured data.
Displays alarm descriptions when an alarm occurs in the inverter during monitoring.
Description