Inverter Reset

(5)
Which resetting method is allowed or not allowed in each operation mode is described below.
Ethernet
Inverter reset (command request network variable)
software
•The inverter can be reset any time.
Turn on the signal across terminals RES-SD.
Power off the inverter.
CAUTION
1. The inverter can not be reset using the Ethernet software (PC) at a communication line fault.
2. Resetting the inverter in the network operation mode places it in the external operation mode.
To resume network operation, therefore, the operation mode must be switched to the network
operation again. (This switchover is not needed when "1" is set in Pr. 304 "link startup mode
selection". Refer to page 51.)
3. During an inverter reset, communication is interrupted about 1 to 2 mins.
Resetting Method
Network
operation
Allowed
Allowed
Allowed
55
Operation Mode
External
PU
operation
operation
Disallowed Disallowed
Allowed
Allowed
Allowed
Allowed