5.3 IP Specific Serial Commands

HSM matrix equipped with IP interface allows user to assign Static IP address using
Serial Interface with standard RS-232. Please refer section 4 to connect PC to Matrix
over serial interface. Once you are connected use following Commands to assign IP
address or load factory defaults. As with all other commands, baud rate is 115kbps
5.3.1 Change network settings of unit
Note: All commands are case sensitive
IP<space><ip_address_value><cr>
Command:
ERR! IP address is either Invalid Or not changed
Error Response:
Success Response:
SB<space><subnet_address_value><cr>
Command:
value
ERR! SUBNET address is not valid.
Error Response:
Success Response:
GW<space><gateway_address_value><cr>
Command:
address value
ERR! GATEWAY Address is not valid.
Error Response:
Success Response:
User MUST enter ALL THREE Commands mentioned above with correct values
and must get 'success response' for each to change IP address.
Following message confirms that user has got 'success response' for all above
commands and device is now applying user settings:
WAIT until you see following Welcome message on Screen. It confirms that device
has done with applying settings and serial interface is ready for other commands.
"Welcome to Hall Research HSM matrix serial interface.
Please refer to user manual for matrix serial commands."
30
IP=<ip_address_value>
SUBNET=<subnet_address_value>
GATEWAY=<subnet_address_value>
"Applying settings to Matrix please wait"
stands for new IP address value
stands for new Subnet address
stands for new gateway