5.0 Network Settings

As shipped from the factory (or after restoring factory defaults), the HSM-88-4K
IP address is set for static IP address of 192.168.1.1. To change the IP or to
switch to DHCP, you can use either RS-232 or Telnet.
For example, to use the RS-232 port to change the IP address do the following:
Connect a PC with Terminal-Emulator software to the RS-232 port
DHCPn command can be used to change DHCP setting
Please see the next section with further information on commands
6.0 Serial & Telnet Commands
Telnet port is 6324, RS-232 port settings are:
Baud rate: 115200, Parity: None, Stop: 1-bit
• Commands are in ASCII format.
• Commands are case sensitive.
• Use a single <CR> character to terminate each command.
• Responses from the Matrix are terminated with <CR><LF>.
• Other than Power command (PW1), the matrix must be powered on.
• Unknown commands respond with "INVALID COMMAND"<CR><LF>.
• After plugging power to the matrix, you must wait ~45 seconds for it to fully
boot up before sending any commands.
• Command characters should be sent continuously without pauses. If you
pause for more than 5 seconds, the command will not execute.
• When the front panel buttons are used, some serial commands will be sent
out the RS-232 port.
Command
n= Output [1-8]
CVn,m
m= Input [1-8] or
m=x to blank Output
(x must be lower case)
m= Input [1-8]
CV*,m
m=x to blank Output
(x must be lower case)
Connect Video
Description
output n to input m
Connect all Outputs to
Input m
© Copyright 2018 Hall Research, Inc.
4K 8X8 HDMI Matrix Switch
Response
CVn,m
CV1,m
CV2,m
:
CV8,m