Before the Platinum Spot 5R Pro™ is put into operation be sure all covers
have been replaced, otherwise you risk damage to the retina and expose to
UV radiation!
When replacing an old lamp, always be sure to replace with an approved
replacement. In this case a Philips MSD Platinum 5R lamp is required. Be
the replacement lamp meets or exceeds the original lamp specifications,
so may damage the fixture and void the manufactures warranty.
Be sure to follow all the lamp handling procedures included with the new
lamp. Never handle the new lamp with your bare hands as the oils from your
may damage the lamp and cause premature lamp failure.
Installation Procedure:
1. Set the fixture on a flat surface and remove the two screws marked "A" and "B".
2. Remove the cover plate to access the lamp.
3. Gently remove the old lamp by grasping the ceramic socket base and twisting it
slightly in counter-clockwise direction until it becomes free.
4. Once the lamp becomes free, grasp the ceramic socket and gently pull away from
the lamp.
5. Insert the new lamp securely. The lamp will only seat one way, please be sure to
insert the lamp in the same position as the old one. Before reassembling the unit, be
sure the new lamp is securely seated in the lamp socket. Always be sure to only use
specified lamp types! (Philips MSD Platinum 5R).
6. Once the lamp has been inserted and secured into the socket, follow the lamp
optimization instructions outlined below, then lock the lamp cover back in to place by
securing screws "A" and "B".
©Elation Professional, Los Angeles, Ca
14
www.ElationLighting.com
Platinum Spot 5R Pro™
sure
failure to do