SPECIAL FEATURES : AIR CONDITIONING SYSTEM (R 134.a)
Drying cartridge
[1] Filling and recycling station
[2] TORX adaptor
[3] After Sales kit
Reminder : All repairs on an aircon circuit require the aircon circuit to be drained.
After carrying out the dismantling operations necessary to gain access to the condenser, proceed to clean
the area of the skirt (8) of the reservoir (6) using a cloth, then replace the dryer reservoir (6).
Removing the plastic bracket holding the reservoir (6) :
- Remove the screw (3) (Torx 20), from the bracket assembly/plastic counter-bracket (4) and (5).
- Remove the counter-bracket (5).(Rotate it round the hinge in a clockwise direction).
- Disengage the bracket from the harness (1) (Rotate it round the reservoir (6) anti-clockwise).
- Remove the bracket (5) from the reservoir body (6).
Unscrewing the reservoir (6).
- Unscrew the reservoir (6) using the tool [2].
226
Tools
MULLER - ECOTECHNICS
70 FACOM