I. Control Module Operation
1. The control module has an ON/OFF/REMOTE selector
switch that must be set. See Figure 2.4.
OFF Position: Appliance will ignore all power inputs and
will not respond to any commands from a wall switch or
remote. The unit should be in the OFF position during
installation, service, battery installation, fuel conversion,
and in the event that the control goes into LOCK-OUT
mode as a result of an error code.
ON Position: Appliance will ignite and run continuously
in the HI fl ame setting, with no adjustment in fl ame
output. This mode of operation is primarily used for
initial installation or power outage operation with battery
backup.
REMOTE Position: Appliance will initiate commands
from a standard wireless wall switch (RC100) and/or
the optional wireless remote (RC200 or RC300).
2. The control module has safety feature that automatically
shuts down the fi replace after 9 hours of continuous
operation without receiving a command from the wall
switch or remote.
3. If you intend to use both an optional wired wall switch
and the optional remote control to operate your
fi replace, the wall switch will override any commands
given by the remote.
4. Module Reset
This module may lock-out under certain conditions.
When this occurs, the appliance will not ignite or
respond to commands. The module will go into
lock-out mode by emitting three audible beeps, then
continuously displaying a RED/GREEN error code at
its status indicator LED.
Locate the module selector switch. (See Figure 2.4).
Set the module selector switch to the OFF position.
• Wait fi ve (5) minutes to allow possible accumulated gas
to clear.
Set the module selector switch to ON or REMOTE
position.
Start the appliance.
WARNING! Risk of Explosion! DO NOT reset the mod-
ule more than one time within a fi ve minute time period.
Gas may accumulate in fi rebox. Call a qualifi ed service
technician.
Heat & Glo •
LUX36, LUX42 • 2287-900
• 2287-900 Rev. J
MODULE
FLAME HI/LOW
SWITCH
INDICATOR LED
Figure 2.4 Control Module
Note: The LUX36 and LUX42 have a fi xed valve.
Flame height is non-adjustable on these models.
Nine Hour Safety Shutdown Feature
This appliance has a safety feature that automatically
shuts down the fi replace after 9 hours of continuous
operation without receiving a command from the wall
switch or remote.
J. Before Lighting Fireplace
Before operating this fi replace for the fi rst time, have a
qualifi ed service technician:
• Verify all shipping materials have been removed from
inside and/or underneath the fi rebox.
• Review proper placement of logs, ember material and/or
other decorative materials.
• Check the wiring.
• Check the air shutter adjustment.
• Ensure that there are no gas leaks.
• Ensure that the glass is sealed and in the proper position
and that the integral barrier is in place.
WARNING! Risk of Fire or Asphyxiation! DO NOT op-
erate fi replace with fi xed glass assembly removed.
Rev. J
• 6/13
SELECTOR
SWITCH
STATUS
NG/LP GAS-TYPE
SELECTOR SWITCH
11