Inspecting The Venting System; Test Chimney Draw; First Firing - Majestic fireplaces NVC36 Operating Instructions Manual

Decorative gas fireplace
Table of Contents

Advertisement

NVC36
NVC39
NVC43
Fig. 16 Approximate flame heights for each model.
FP393
8/25/98

Inspecting the Venting System

NVC FLAME HEIGHTS
This appliance venting system is designed and con-
structed to develop a positive flow adequate to remove
flue gases to the outside atmosphere.
Any foreign objects in the venting system, except those
designed specifically for the venting system, may cause
spillage of flue gases.
To inspect the venting system, make sure the main gas
valve is off. Remove the window frame assembly (Refer
to Page 10). Using a flashlight, check the area above
the baffle in the combustion dome. Clean if necessary.
20000194
A "Chimney Draw" test must be made before the instal-
lation is complete.
1. Close all doors and windows in the home and start
exhaust fans in the kitchen and bathroom.
2. Light unit and operate for 5 minutes.
3. Hold an ignited match, cigarette, or smoke match in
front of the unit. Refer to Figure 17 for location of the
draft hood opening.
4. Check to make sure smoke from the match, cigarette
or smoke match is drawn into the fireplace. If it is
not, turn the unit off and check for causes creating
the lack of adequate draft.
Do not operate the unit until lack of ad-
equate draft has been determined and
rectified.
FP393
Fig. 17 Draft test location.
Remove window frame assembly before lighting.
Upon completing the gas line connection, a small
amount of air will be trapped in the line. When first
lighting the unit with pilot light, it will take a few minutes
to purge the trapped air. Once purging is complete, the
pilot and burner will light and operate as indicated in the
instruction manual. Subsequent lightings of the appli-
ance will not require purging.
When lit for the first time, the appliance will emit a slight
odor for awhile. This is due to paint and lubricants used
in the manufacturing process. After each lighting, vapor
may condense and fog the glass; this moisture disap-
pears within a few minutes of burning.
NVC Series B-Vent

Test Chimney Draw

Test for Draft at This Location

First Firing

FP1197
draft test location
2/27/02 djt
FP1197
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nvc39Nvc43

Table of Contents