EB-1 Electrical Box

The fireplace, when installed, must be
electrically connected and grounded in
accordance with local codes or, in the ab-
sence of local codes, with the current CSA
C22.1 Canadian Electrical Code.
For USA installations, follow local codes
and the National Electrical Code, ANSI/
NFPA No. 70.
It is strongly suggested that the wiring of
the EB-1 electrical junction box be carried
out by a licensed electrician.
Ensure that the power to the supply line
has been disconnected before commenc-
ing this procedure.
Once the fireplace is secured, complete wiring the fan
kit. Remove knockout in the center of the back of the
EB1 and install listed cable clamps. Feed electrical
wire through cable clamp leaving approximately six (6)
inches of wire exposed through the EB1. Secure cable
clamp to the wire.
Attach white wire from power source to one (1) wire of
receptacle and secure with a nut. Attach black wire from
power source to the other wire of the receptacle and
secure with a nut. Be sure nuts are tightened securely.
Secure the EB1 assembly to the inside of the electrical
box coverplate using two (2) screws. Attach the cover
to the face of the EB1 while being careful to position
excess wire completely within the EB1. Attach the cov-
erplate to the fireplace. (Fig. 9)
Inside
Outside
Fig. 9 Junction box (EB-1) hook-up.
7412958
Electrical Box
FP580
FP580
INSTA VENT FREE
EB1 JUNCTION BOX
11/18/97
Install the Venting System,
Flashing, and Termination
See venting installation instructions provided by the B-
Vent manufacturer.
Refer to Page 4, Figure 1 to locate chimney centerline
dimension from a combustible back wall.
• Minimum vertical chimney height — 12 feet (3.65m).
• Maximum vertical height — 40 feet (12m).
• Minimum height with two 90° elbows — 16 feet
(4.06m)
• Elbow requirements allow a maximum of two
90 degree elbows or four 45 degree elbows
per installation. (Two 45 degree elbows =
One 90 degree elbow.) See venting chart for
proper elbow offset runs. Use Figure 11 for all
NVCVR installations and NVSTR installations when
not installing 36GSKBB Single Panel Glass Door.
Use Figure 12 for NVSTR installations when using
36GSKBB Single Panel Glass door.
For firestop positioning, refer to Figure 10. Only one
(1) firestop required per frame. NOTE: A firestop is not
required at the roof.
Attic Installation
Firestop position when area above ceiling is an attic.
Ceiling Installation
Firestop position when area above ceiling is NOT an attic.
Fig. 10 Firestop/ draftstop positions.
FP384
FIRESTOP
11/21/96
rev 1-10-03
NVSTR/ NVCVR Series
Nails (4)
Firestop Spacer
Joist
NOTE: Firestop/draftstop
appearances may vary.
Only one (1) firestop is
required per frame.