Framing and Finishing

Check fireplace to make sure it is levelled
and properly positioned.
1. Choose the unit location.
2. Place the unit into position and secure it to the floor
with 1¹⁄₂" (38mm) screws, or nails. The holes to
secure the unit to floor are located just behind the
access door grille on the left and right side of the
unit.
3. Frame in the fireplace with a header across the top.
It is important to allow for the finished wall face when
setting the depth of the frame.
4. Attach the fireplace to the frame using the adjustable
frame drywall strips (located behind the access door
for shipping). Preset the depth to suit the facing
material of the wall. The strips are adjustable to 1/2"
(13 mm), 5/8" (16 mm), or 3/4" (19 mm). (Fig. 4)
5. Screw through the slotted holes in the drywall strip
and into pre-drilled holes in fireplace side. Measure
from face of fireplace to the face of the drywall strip
to confirm the final depth.
A
B
C
Fig. 4 Adjustable drywall strip (nailing flanges).

Final Finishing

Noncombustible materials such as brick or tile may be
extended over the edges of the face of the appliance.
DO NOT cover the window frame assembly, any
vent, louvre top assembly or louvre bottom assem-
bly.
If a Trim Kit is going to be installed on the fireplace, the
brick or tile will have to be installed flush with the edges
of the appliance.
20000194
Adjustable Drywall Strip
(Nailing Flange)
Screw
Drywall
Position
Depths
A
1/2" / 13 mm
B
5/8" / 16 mm
C
3/4" / 19 mm
Adjustable
1/2", 5/8" &
3/4" Spacing
FP1023
FP1023
side nailing flange
1/27/00 djt
Gas Specifications
Model
Fuel
Gas Control
NVC36RN
Natural
Millivolt Hi/Lo
NVC36RP Propane
Millivolt Hi/Lo
NVC36VN
Natural
NVC36NP Propane
NVC36EN
Natural
Electronic Ignition
NVC36EP Propane Electronic Ignition
NVC39RN
Natural
Millivolt Hi/Lo
NVC39RP Propane
Millivolt Hi/Lo
NVC39VN
Natural
NVC39VP Propane
NVC39EN
Natural
Electronic Ignition
NVC39EP Propane Electronic Ignition
NVC43RN
Natural
Millivolt Hi/Lo
NVC43RP Propane
Millivolt Hi/Lo
NVC43VN
Natural
NVC43VP Propane
NVC43EN
Natural
Electronic Ignition
NVC43EP Propane Electronic Ignition
NOTE: VN and VP models are for use the PVS-1 Power
Vent System.
Gas Inlet & Manifold Pressures
Minimum Inlet Pressure
Maximum Inlet Pressure
Manifold Pressure

High Elevations

Input ratings are shown in BTU per hour and are
certified without deration for elevations up to
4,500 feet (1,370m) above sea level.
For elevations above 4,500 feet (1,370m) in USA,
installations must be in accordance with the
current ANSI Z223.1/NFPA 54 and/or local codes
having jurisdiction.
In Canada, please consult provincial and/or local
authorities having jurisdiction for installations at
elevations above 4,500 feet (1,370m).
NVC Series B-Vent
Max.
Input
25,000
17,500
25,000
18,750
24V Hi/Lo*
25,000
17,500
24V Hi/Lo*
25,000
18,750
25,000
17,500
25,000
18,750
30,000
21,000
30,000
22,500
24V Hi/Lo*
30,000
21,000
24V Hi/Lo*
30,000
22,500
30,000
21,000
30,000
22,500
33,000
23,100
33,000
24,750
24V Hi/Lo*
33,000
23,100
24V Hi/Lo*
33,000
24,750
33,000
23,100
33,000
24,750
Natural
LP
5.5" w.c.
11.0" w.c.
14.0" w.c.
14." w.c.
3.5" w.c.
10.0" w.c.
Min.
Input
7