Bosch MIC440 Operation Manual page 18

Explosion-protected camera
Hide thumbs Also See for MIC440:
Table of Contents

Advertisement

18
en | Installation of a MIC440 Camera
Installation of the PSU within a hazardous area must have the standard PSU enclosure placed
inside an appropriate certified enclosure and four (4) Exd conduit glands (NOT supplied). The
power supply PCB is usually re-housed, by a third party company, within an Exd enclosure
which is then factory certified and shipped to site. Follow all manufacturers' instructions when
installing a third party Exd enclosure.
The figure below illustrates a typical installation of both a MIC440 and a MIC PSU in a
hazardous area. Note that the PSU is installed inside an enclosure that is certified for use in
hazardous areas.
Figure 5.2: Installation of MIC PSU in Hazardous Area
No.
Description
1
MIC440 camera
2
MIC440 DCA
3
MIC Wall Mount Bracket (not supplied)
4
Exd conduit gland
Exd Barrier Gland (not supplied; to be specified by installer to match incoming conduit)
5
MIC composite cable (length to be specified; 25 m maximum) inside metal conduit (not supplied)
6
MIC PSU
7
Hazardous area
8
Non-Hazardous area
9
Exd Enclosure certified for hazardous areas (not supplied)
2013.11 | 8.1 |
Operation Manual
MIC440 Explosion-protected Camera
Bosch Security Systems, Inc.

Advertisement

Table of Contents
loading

Table of Contents