SITE PREPARATION

Electrical

Installation must comply with all applicable electrical codes.
The electrical supply should be located within the shaded
area shown in the illustration below. A separate circuit, ser-
vicing only this appliance is required. A ground fault circuit
interrupter (GFCI) is not recommended and may cause inter-
ruption of operation.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
Receptacle
CAUTION
The outlet must be checked by a qualified electrician to
be sure that it is wired with the correct polarity. Verify
that the outlet is properly grounded.
WARNING
Do not use an extension cord, two-prong adapter or
remove the power cord ground prong.
7"
E
(178)
6"
(152)
1
75
/
"
2
(1918)
FROM FLOOR
RIGHT SIDE
OF OPENING
Electrical supply location.
115 VAC, 60 Hz
15 amp
3-prong grounding-type

Plumbing

Installation must comply with all applicable plumbing codes.
The water supply line should be located within the shaded
area shown in the illustration below. The water supply line
should be connected to the house supply with an easily
accessible shut-off valve. Do not use self-piercing valves.
The water supply line must not interfere with installation of
the anti-tip bracket.
A reverse osmosis system can be used provided there is
constant water pressure of 35–120 psi
to the unit at all times. In this application, the water filtration
system must be bypassed by removing the filter. A copper
line is not recommended for this application.
PLUMBING REQUIREMENTS
Water Supply
Pressure
Excess Line for Connection
RIGHT SIDE
OF OPENING
3
6"
5
/
"
16
(152)
(132)
3"
(76)
AREA EXTENDS 1
/
"
2
(13)
FORWARD ON FLOOR
Water supply location.
supplied
(2.4–8.3 bar)
1
/
" OD copper, braided
4
stainless steel or PEX tubing
35–120 psi
(2.4–8.3 bar)
36"
(914)
|
subzero.com
5