Carrier 30AWH004HB Service Manual page 96

Table of Contents

Advertisement

Code Nr.
Name
OUTDOOR
( )
11
TEMPERATURE
GMC OUTDOOR AIR
( )
12
TEMPERATURE
TEMPERATURE ROOM
13
SENSOR ADJUSTMENT
14
DAY PERIOD
HOME HEAT TEMPE-
15
RATURE
HOME COOL TEMPE-
16
RATURE
SLEEP HEAT
17
TEMPERATURE
SLEEP COOL
18
TEMPERATURE
AWAY HEAT
19
TEMPERATURE
AWAY COOL
20
TEMPERATURE
USER ROOM
( )
21
SET-POINT
FAULT CODE
( )
22
FAULT HISTORY
( )
23
100
SYSTEM TYPE
101
USER INTERFACE TYPE
NUI SOFTWARE
( )
102
RELEASE
NUI SOFTWARE
( )
103
VERSION
104
OUTPUT TEST
RESET PUMP
105
RUN-TIME
EXTERNAL HEAT
106
SOURCE / DEFROST
107
HUMIDITY LIMIT
SM_30AW.indd 96
DESCRIPTION
This code displays the Outdoor Air Temperature. The valid OAT
value is used with this priority:
1. OAT from GMC thermistor (if it is installed)
2. OAT from inverter, read by TO sensor.
This code displays the Outdoor Air Temperature read by GMC
thermistor.
This code is use to adjust the temperature read by the sensor in
order to recover bad positioning of the user interface.
This code is use to select how many period per day will be availa-
ble for the scheduling:
2
4
6
With this code the User can select the HOME Temperature set-
point in Heating Mode
With this code the User can select the HOME Temperature set-
point in Cooling Mode
With this code the User can select the SLEEP Temperature set-
point in Heating mode
With this code the User can select the SLEEP Temperature set-
point in Cooling Mode
With this code the User can select the AWAY Temperature set-
point in Heating mode
With this code the User can select the AWAY Temperature set-
point in Cooling Mode
This code displays the room set-point that the user, pressing the
temporary/hold button, is selecting as temporary or hold.
This code displays the last fault code occurred.
This code displays the recent 4 fault codes stored.
This code is use to set the System type:
1.
A2W Monobloc fixed Water Temperature Value (dry contacts)
2. A2W Monobloc Climatic Curve setup (dry contacts)
3. A2W Monobloc Comfort with NUI
4. A2W Monobloc Comfort with NUI as Thermostat
5. N.A.
6. A2W Monobloc RS485
7. N.A.
This code is use to define if NUI User Interface is used and how it
is used:
0.
Not Used (Input Relay active/SUI)
1.
NUI Installed
2.
NUI used as programmer
This code displays the NUI Software Release
This code displays the NUI Software Version
This code is use to force Output ON to test (max 10 minutes):
0. No test
1. Water pump
2. Alarm / Ambient temperature reached
3. External Heat Source / Defrost
4. Alarm + Defrost / Humidity
5. Trace Heater / Additional Water Pump
6. 3 Way valve
7. SUI Alarm
8. Blank
This code is use to reset the water pump timer to zero.
This code is use to select the output connected at PIN 4 on
terminal strip:
1. External Heat Source
2. Defrost Output
This code is use to define the humidity threshold limit to enable
the output for the external de-humidifier system.
Carrier interfaces
VALUE RANGE
Min
-30°C
-
-5°C
2
12°C
12°C
12°C
12°C
12°C
12°C
12°C
-
-
1
0
-
-
0
no
1
20
96
7
STANDARD
Max
90°C
-
-
-
+5°C
0°C
6
4
38°C
20°C
38°C
24°C
38°C
18°C
38°C
26°C
38°C
15°C
38°C
28°C
38°C
20°C
-
-
-
-
7
1. A2W
2
0. Not used
-
-
-
-
9
0. No test
yes
no
2
1
100
30AW
14-03-2011 14:46:19