3.3.8 Water loop charging, system cleaning and Water Characteristics

Charge the water loop, with water, until the pressure on the hydro unit
reads 0.15MPa (1.5bar )
Setting NUI Code104 (installation mode) = 1 water pump is forced on.
Loosen the cap of the air purge valve located on the top of back up
heater to purge air from the water circuit. If air remains in the system the
system will not operate correctly.

3.3.9 Expansion vessel (Volume calculation)

An expansion vessel has to be added in the water loop with 30AWH___X
and 30AWH___NX.
The capacity of the internal expansion vessel fitted in 30AWH__H :
has been dimensioned for a typical terminal fan coil water loop)
If water loop content is higher than specified in the installation manual,
an additional expansion vessel has to be added.
The expansion volume can be calculated using the following formula.
V
Water temperature and expansion coefficient (ε)
Hot water temperature (°C)
0
4
5
10
15
20
25
30
35
40
45
Example: Maximum hot water temperature 55°C, initial water charge 0.2MPa and system volume 200 litres. The calculated Vessel capacity is:
SM_30AW.indd 18
Vs
P
1
1
P
2
Expansion rate (ε)
0.0002
0.0000
0.0000
0.0003
0.0008
0.0017
0.0029
0.0043
0.0050
0.0078
0.0100
11
6 .
Looking for Code 111 (water flow switch status) the installer can verify if
the water fill operating is completed (when water is flowing, parameter
111 = 1)
When completing the Test Run, during the commissioning of the
system, the water pressure in the system may drop below 1,5 bar. In this
event please add more water to the system.
In the case of a new installation, or cleaning the circuit, it is necessary to
perform a preventive cleaning of the system.
In order to guarantee the good operation of the product, each time you
clean the system, replace the water or add glycol, check that the liquid
appears clear, without visible impurities and that the hardness is less
than 20 °f.
Where:
V: Necessary total vessel capacity (L)
Vs: Total water volume in the closed system (Do not include Hot Water
Cylinder)
P1: System pressure at tank setting position (Mpa_abs*). (Pipe inner
pressure during pump operation before heating device operates =
water supply pressure)
P2: Maximum pressure used during operation at tank setting position
(Mpa_abs*=safety valve setting pressure)
* The absolute pressure valve (abs.) is obtained by adding the atmos-
pheric pressure (0,1 MPa (1 bar)) to the gauge pressure.
The initial pressure of this expansion Vessel is 0.1Mpa (1 bar).
The release pressure of the safety valve is 0.3Mpa (3 bar).
Water temperature and expansion coefficient (ε)
Hot water temperature (°C)
50
55
60
65
70
75
80
85
90
95
-
. 0
0145
200
0 (
2 .
0
) 1 .
1
0 (
3 .
0
) 1 .
18
3
Installation
Expansion rate (ε)
0.0121
0.0145
0.0171
0.0198
0.0229
0.0258
0.0292
0.0324
0.0961
0.0967
-
30AW