Bosch 2600 Series Instruction Manual page 12

System4 video controllers command console language
Table of Contents

Advertisement

LTC 2600 Series | Instruction Manual | Multiplexer Set (MS) Commands
MS-ACTION-SENSITIVITY <camera#> <level>
This command sets the action detector sensitivity for
each specified camera to a certain level.
Parameter values for <camera# > and <level > are as
follows:
<camera# >
1 to 16
<level>
1 to 4 (with 4 being the highest
sensitivity)
MS-ACTION-SETUP <boolean> <boolean>
This command sets the action manual reset and
camera history settings, respectively.
Parameter values are:
MS-ACTION-ZONEDRAW <zone draw setting>
NOTE: This command is only supported for binary
protocol.
This command enables or disables real-time zone
drawing on monitor A.
Parameter values for <zone draw setting> are:
0
Disabled
camera#
Enabled; the specified camera is
selected for monitor A in full-screen
mode, and real-time drawing is
enabled for that camera-overriding
any other use of monitor A.
MS-ACTION-ZONEGROUP <camera#> <table 8>
This command enables more detailed, specialized
setup of groups of action detector zones. (Individual
action zone selection is normally accomplished using
monitor A and the front panel keypad.)
Parameter values for <camera# > range from <1> to
<16>. Parameter values for <table 8> range from <0>
to <255> (decimal) OR <0> to <FF> (hex). Table 8 is
an 8-position (bit) table where the value in each
position corresponds to the state of a specific action
detection zone group (i.e. <1> enables the zone group;
<0> disables the zone group.)
EXAMPLE: To enable camera number 1, action
detection zone groups 4, 7, and 8; a value of <1> is
used for <camera#>, and a value of <200> decimal
(C8 hex) is used for <table 8>.
Bosch Security Systems | July 12, 2004
0
Disabled
1
Enabled
Monitor Zone Groups
1 2 3 4
5 6 7 8
Zone Group No.: 8 7 6 5 4 3 2 1
Position (Bit) #
7 6 5 4 3 2 1 0
Zones 4, 7, and 8 Enabled, Table Value 200:
(C8 hex)
1 1 0 0 1 0 0 0
Table 8
MS-ACTION-ZONES <camera#> <map row#>
<zone map row>
This command sets the specified map row in the action
zone map for the specified camera.
Parameter values for <camera#>, <map row#>, and
<zone map row> are defined as follows:
<camera# >
<map row#>
<zone map row>
MS-ACTIVE-CAMEO <monitor> <cameo#>
This command sets the specified cameo as the active
cameo for the specified monitor. Any non-valid
<cameo#> will be ignored.
Parameter values for <monitor> and <cameo#> are as
follows:
<monitor>
<cameo#>
MS-ADDRESS <unit address>
This command sets the unit address for the
multiplexer. The unit address is used by the external
keyboard to select a particular multiplexer. Each
multiplexer in the system must have a unique address,
although this cannot be verified automatically by the
multiplexer.
Parameter values for <unit address> range from
<1> to <30>.
EN | 12
1 to 16
1 to 16
A 16-bit word, corresponding
to the map row points where
the zone map bit 0 is the
most right point, and the
zone map bit 15 is the most
left point.
1
Monitor A
2
Monitor B
1 to 16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ltc 2600 series

Table of Contents