EXAMPLE: To activate pre-position # 16 on camera #
1, enter the following command: LTC 2600>R/C 1 2 15
NOTE: Since the decimal mode is being assumed, the
numeric value for the data was selected from the
decimal column in the table. Also note that the actual
number of seconds a time-dependent command will be
activated may only approximate the value entered.
RESET-SYSTEM
This command resets the system (simulates a power
off/on cycle).
REVISION
This command returns the current software revision.
EXAMPLE: For Engineering release E13 1.01, the
value returned is: LTC 2600> E13 1 1
For full release 1.02, the value returned is:
LTC 2600> 1 2
SET-RS-232 <baud> <data bits> <parity> <stop bits>
<handshake>
This command sets the RS-232 communication
parameters: baud rate, data bits, parity, stop bits, and
handshake (in that order).
Parameter values are:
<baud>
0 / 1 / 2 (600 / 1200 / 2400)
3 / 4 / 5 (4800 / 9600 / 19200)
<data bits>
7 or 8 (data bits)
<parity>
0 / 1 / 2 (none / even / odd)
<stop bits>
1 or 2 (stop bits)
<handshake>
0 or 1 (OFF / ON)
EXAMPLE: To select a baud rate of 9600, 8 data bits,
no parity, 1 stop bit, and hardware handshaking off:
<4> is used for "baud", <8> is used for "data bits",
<0> is used for "parity", <1> is used for "stop bits",
<0> is used for "handshake". LTC 2600> SET-RS-232
4 8 0 1 0
Bosch Security Systems | July 12, 2004
TIME
This command displays the system time.
!TIME
To set the time in the system, enter the time in the 24
hour format in the form below: LTC !TIME 13 00 00
VARSPEED_PTZ <logical cam#> <pan speed> <tilt
speed> <zoom speed> <function code>
This command selects the variable speed functions of
the AutoDome Series of dome cameras. Once a
variable speed command is received by the
AutoDome, it will continue to operate until the "All
Off" or another control command is received.
Parameter values are:
<logical cam#>
<pan speed>
<tilt speed>
<zoom speed>
<function code>
Function
Hex
all off
000
pan right
001
pan left
002
tilt down
004
tilt up
008
zoom out
010
zoom in
020
focus near
040
focus far
080
iris close
100
iris open
200
EN | 42
1 to 999 (maximum
number of cameras)
0 to F (hex)--where
0 = slowest, F = fastest
0 to F (hex)-where
0 = slowest, F = fastest
0 to 7-where 0 = slowest,
7 = fastest
See following table
Decimal
0
1
2
4
8
16
32
64
128
256
512