LTC 2600 Series | Instruction Manual | Multiplexer Set (MS) Commands
MS-CAM-VIDEOLOSS-MESS <table 16>
This command enables or disables video loss messages.
The <table 16> parameter ranges in value from <0> to
<65535> (decimal) OR <0> to <FFFF> (hex). Table
16 is a 16-position (bit) table where the value in each
position corresponds to the video loss messages status
of a specific camera (i.e. a value of 1 enables video loss
messages; a value of 0 disables the video loss
messages).
NOTE: Video loss messages can be disabled for
connected or disconnected cameras. When a camera
with videoloss message disabled is connected to the
system, the videoloss message is not automatically
enabled (i.e. the command must be given to enact a
change in this function).
EXAMPLE: To disable video loss messages related to
camera 1, a value of <65534> decimal (FFFE hex) is
used for <table 16>.
Camera No:
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
Position (Bit) #:
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
1-4 Enabled, Table Value 15:
(000F hex)
0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1
MS-DISPLAY-MODE <monitor> <display-mode>
This command sets the display mode for the specified
monitor.
Parameter values for <monitor> and <display-mode>
are:
<monitor>
1
2
<display-mode> 0
1
2
3
4
5
6
NOTE: Selecting Quad mode will loop between
available quad modes. For non-duplex, System4 units,
only Full Screen mode will be accepted for monitor B.
Bosch Security Systems | July 12, 2004
Monitor A
Monitor B
Full Screen
Single Quad
3 x 3 Multi
4 + 3 Multi
12 + 1 Multi
4 x 4 Multi
8 + 2 Multi
MS-FREEZE <monitor> <cameo#> <boolean>
This command enables or disables the freeze function
for the specified cameo on the specified monitor.
NOTE: If the specified monitor is in full screen mode,
the cameo specification is redundant (i.e. unnecessary).
Parameter values for <monitor>, <cameo#> and
<boolean> are:
<monitor>
1
2
<cameo#>
1
<boolean>
0
1
MS-HELP
This command displays a screen of help instructions
regarding MS command entry.
MS-KEY-LOCKOUT <boolean>
This command sets or clears the lockout flag for the
front panel and external keypad. When set, all front
panel and external keystrokes are ignored. PTZ
commands continue to be accepted from the external
keypad.
Parameter values are:
MS-LANGUAGE <language>
This command specifies the language for the
multiplexer.
Parameter values for <language> are:
1 English
2 German
3 French
4 Spanish
5 Italian
6 Dutch
EN | 15
Monitor A
Monitor B
to 16
Disable
Enable
0
Disabled
1
Enabled