Installing The Remote Monitor - Cyclo Vac GS Series Owner's Manual

Cyclovac central vacuum system
Table of Contents

Advertisement

Available languages

Available languages

Installing the Remote Monitor

Having determined the location of both
the central vacuum unit and the remote
System monitor, run low voltage wiring to
connect the monitor to the central vacuum
power unit.
Installing the remote Monitor
1. Insert the low voltage wire into the
mounting box through one of the
designated openings, and fasten within
the wall at the determined location
(figure 11).
2. Having stripped the exterior casing of the
four-stranded wire, strip 0,5 cm (¼") of
each color wire.
3. connect wires to the module connector.
Insert each of the 4 color wires in the
corresponding color-coded inlet on the
connector. to do so, loosen the screw on
the side of each inlet, insert the wire, and
tighten screw to ensure a tight connection.
repeat for each of the remaining 3 wires
(figure 12).
4. Insert the connector to the electronic
module and ensure it holds in place
(figure 13).
5. Screw the electronic module to the
mounting box, with the two screws
provided (figure 14).
6. complete with the "Decora" finishing
plate.
16
(Optional — GX series only)
Installation
figure 11
a. red
B. Black
c. Green
D. yellow
figure 12
figure 13
figure 14