Vermont Castings SA18SHKSN Installation And Operation Instructions Manual page 4

Vented gas log sets- hearth kits
Table of Contents

Advertisement

Pre-Installation Checklist
Is the gas supply inlet pressure correct?
NG: Min. 5.5" w.c./Max. 14.0" w.c. LP: Min. 11" w.c./Max. 14.0" w.c.
Does the firebox meet the minimum size dimensions below?
Is your fireplace plumbed with gas on the right side (facing) of the fireplace?
If not, refer to ee Page 5.
Is the gas supply line sized properly (Minimum 1/2" iron pipe)?
Do you have a solid fuel (wood burning) fireplace with a vented flue?
Do you have a manual gas supply valve installed at your fireplace? If not, a licensed
plumber, gas company technician or other qualified installer must install one.
Have you checked local building codes? (Check with your local building department)
Does your fireplace have a wire mesh screen in place?
CAUTION: If you answered "NO" to any item, or have any questions regarding your installation, please con-
tact your dealer/distributor for assistance.
Set
Input
Size
Btu/hr
Back
18"
50,000
16"
24"
75,000
20"
30"
90,000
27"
NOTE: All dimensions are minimums.
Set
Input
Size
Btu/hr
Back
18"
40,000
16"
24"
45,000
20"
30"
60,000
27"
NOTE: All dimensions are minimums.
4
Minimum Clearances & Specifications
Natural Gas Units
Minimum Firebox Dimensions
Width
Front
Depth
33"
15"
36"
15"
39"
15"
Propane Gas Units
Minimum Firebox Dimensions
Width
Front
Depth
33"
15"
36"
15"
39"
15"
Minimum
Flue
Height
Size
18"
51 sq.in.
18"
51 sq.in.
18"
51 sq.in.
Minimum
Flue
Height
Size
18"
51 sq.in.
18"
51 sq.in.
18"
51 sq.in.
Yes
Gas Fuel Line
Pressure
Minimum
Maximum"
5.5"w.c.
14.0"w.c.
5.5"w.c.
14.0"w.c.
5.5"w.c.
14.0"w.c.
Gas Fuel Line
Pressure
Minimum
Maximum
11.0"w.c.
14.0"w.c.
11.0"w.c.
14.0"w.c.
11.0"w.c.
14.0"w.c.
No
Manifold
Pressure
3.5"w.c.
3.5"w.c.
3.5"w.c.
Manifold
Pressure
10.0"w.c.
10.0"w.c.
10.0"w.c.
3311882