INSTALLER / CONSUMER
SAFETY INFORMATION
Please read this manual
before installing and using
appliance.
WARNING: If the information in
this manual is not followed
exactly, a fire or explosion may
result causing property damage,
personal injury of loss of life.
Do not store or use gasoline or
other flammable vapors and liquids in
the vicinity of this or any appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance
Do not touch any electrical switch;
do not use any phone in your building
Immediately call your gas supplier
form a neighbor's phone. Follow the
gas supplier's instructions
If you cannot reach your gas
supplier, call the fire department
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
Installer: Leave this manual
with the consumer.
Consumer: Retain this
manual for future reference.
User's Operation and Installation Manual
Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater
Gas-Fired Room Heater
Models:
VCBV30TN, VCBV30TP - 30,000 Btu/Hr Thermostat
VCBV20TN, VCBV20TP - 20,000 Btu/Hr Thermostat
VCBV10TN, VCBV10TP - 10,000 Btu/Hr Thermostat
Models:
VCPV30TN, VCPV30TP - 30,000 Btu/Hr Thermostat
VCPV18TN, VCPV18TP - 18,000 Btu/Hr Thermostat
VCPV10TN, VCPV10TP - 10,000 Btu/Hr Thermostat
Unvented
Blue Flame Heaters
Plaque Heaters
20003770 8/02 Rev. 1
1

Advertisement

loading

Summary of Contents for Vermont Castings VCBV10TN

  • Page 1 Gas-Fired Room Heater Blue Flame Heaters Models: VCBV30TN, VCBV30TP - 30,000 Btu/Hr Thermostat VCBV20TN, VCBV20TP - 20,000 Btu/Hr Thermostat VCBV10TN, VCBV10TP - 10,000 Btu/Hr Thermostat Plaque Heaters Models: VCPV30TN, VCPV30TP - 30,000 Btu/Hr Thermostat VCPV18TN, VCPV18TP - 18,000 Btu/Hr Thermostat VCPV10TN, VCPV10TP - 10,000 Btu/Hr Thermostat 20003770 8/02 Rev.
  • Page 2: Table Of Contents

    Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater General Safety Information SAFETY: Accidents are always tragic, especially because so many of them could have been prevented with a little care and judgment. There are some basic good practices we hope you will follow for safe use of your gas fired room heater.
  • Page 3: Specifications

    VCBVTN, VCBVTP, VCPVTN and VCPVTP Specifications Input Rating (Btu/Hr) Variable Models Type Min. VCBV30TN 15,000 VCBV20TN Natural 10,000 VCBV10TN 5,000 VCBV30TP 15,000 VCBV20TP 10,000 VCBV10TP 5,000 VCPV30TN 6,400 VCPV18TN Natural 6,400 VCPV10TN 5,500 VCPV30TP 6,400 VCPV18TP 6,400 VCPV10TP 5,500 NOTES: For altitudes above 2,000 feet, reduce the input ratings (Btu/Hr) 4% for each 1,000 feet above sea level.
  • Page 4: Installation

    Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Installation Requirements Fresh Air for Combustion and Ventilation WARNING: This heater must have fresh air for proper opera- tion. If not, poor fuel combustion could result. Read the following instructions to insure proper fresh air for this and other fuel-burning appli- ances in your home.
  • Page 5 This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. *Aftermarket: Completion of sale, not for purpose of resale from manufacturer. This appliance is only for use with the type of gas indicated on the rating plate.
  • Page 6 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater 1/16" (1.6mm) Fig. 4 Wall anchor. Floor Installation 1. The heater may only be installed on a noncombus- tible flat surface. Wall mounting screws may be used to keep heater from side movements. 2.
  • Page 7 Pressure Regulator 3/8” NPT Nipple Tee Joint Reducer Bushing to 1/8” NPT 1/8” NPT Plug Tab Tee Joint Pipe Nipple RH103 Fig. 6 Gas line connection. Pressure Test Gas Supply Piping System The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 1/2 psi.
  • Page 8: Operating Instructions

    Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Operating Instructions FOR YOUR SAFETY - READ THIS SECTION BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLO- SION MAY RESULT CAUSING PROPERTY DAM- AGE, PERSONAL INJURY OR LOSS OF LIFE. A.
  • Page 9 Manual Lighting Instructions 1. Remove lower front panel. 2. Follow steps 1 through 4 as stated under Lighting Instructions. 3. Press and turn control knob counterclockwise to the PILOT position. 4. With control knob pressed in, strike match, hold match to pilot until pilot lights. 5.
  • Page 10: Troubleshooting

    Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Problem When control knob is pressed in and turned counterclockwise to ignition, there is no spark at ODS pilot. When control knob is pressed in and turned counterclockwise to ignition/pilot position, there is spark but no ignition. ODS pilot lights but flame goes out when control knob is released.
  • Page 11: Maintenance

    Troubleshooting, continued Problem Heater produces a clicking noise just after burner is lit or turned off. Gas odor even when control knob is in OFF position. Gas odor during combustion. Heater shuts off on ODS Dust, lint, cobwebs or debris may affect heater perfor- mance.
  • Page 12 Combination Gas Control - Natural 13b. Combination Gas Control - LP Connector - “C” Connector - “B” Tubing ODS Assembly Tubing Outlet Assembly Tubing Inlet Assembly Nozzle Holder 13a,b VCBV10TN/TP RBW33XX0 RBC02XC0 RBP63PC0 RBP71PX0 RBP69PA0 RBI06XX0 RBW13XX0 RBP06XA0 RBP06XB0 RBW31PA0...
  • Page 13 ODS Pilot Assembly (Daemyeong Korea) - LP Shield Rear Radiant Heat Shield 25a. Pressure Regulator (Daemyeong Korea) - Natural 25b. Pressure Regulator (Daemyeong Korea) - LP Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater VCBV10TN/TP RBM08XX0 RBM07XEO RBM07XF0 DS98JN02 DS98JL02 RBP100 DR40M2PN...
  • Page 14 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater 20a,b 23a,b 18a,b The Vermont Castings Majestic Products Company reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. VCPVTN/ TP Unvented Room Heater Item / Model Number Cover Heat - Lower Guard Assembly...
  • Page 15: Replacement Parts

    VCPVTN/TP, continued Item / Model Number 20a. Main Nozzle - Natural 20b. Main Nozzle - LP Rear Radiant Heat Shield Shield 23a. Pressure Regulator (Daemyeong Korea) - Natural 23b. Pressure Regulator (Daemyeong Korea) - LP The following accessories are available from your local Vermont Castings dealer. Each accessory comes with a separate installation instruction.
  • Page 16 Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater Warranty Service and Limited Warranty The Vermont Castings Majestic Products Company warrants this product to be free form defects in materi- als and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accor- dance with all applicable instructions.