Allen-Bradley 1203-SSS User Manual page 31

Powerflex smart self-powered serial converter
Hide thumbs Also See for 1203-SSS:
Table of Contents

Advertisement

Table 4.B DPI Mode
Events
Description
Bad Host Flt
The serial converter was connected to an incompatible product.
Control Disabled
The serial converter has sent a "Soft Control Disable" command to the DPI
product.
Control Enabled
The serial converter has sent a "Soft Control Enable" command to the DPI
product.
DPI Bus Off Flt
A bus-off condition was detected on DPI. This event may be caused by loose or
broken cables or by noise.
DPI Fault Clear
A DPI product has issued a fault clear message.
DPI Fault Msg
The drive entered a faulted state.
Dup. Port Flt
Another peripheral with the same port number is already in use.
EEPROM Sum Flt The EEPROM in the serial converter is corrupt.
Host Sent Reset
The DPI product issued this because it was reset.
Message Timeout The DPI product did not respond to a message request. Verify the cables are
correct.
No Event
Empty event queue entry.
Normal Startup
Adapter initially powered up or was reset.
Online @ 125kbps The serial converter and DPI product are communicating at 125kbps.
Online @ 500kbps The serial converter and DPI product are communicating at 500kbps.
PCCC I/O Time Flt The serial converter has not received a PCCC Control message for longer than
the specified PCCC Control Time-out.
Ping in Message
An unexpected ping was received.
Ping Time Flt
A ping message was not received on DPI within the specified time.
Port Change Flt
The DPI port changed.
Port ID Flt
The serial converter is not connected to a correct port on a DPI product.
Type 0 Login
The serial converter has logged in for type 0 control.
Type 0 Time Flt
The serial converter has not received a type 0 status message within the
specified time.
Use I/O Sent
The serial converter has begun sending product specific control information.
To clear the event queue
1. Access the event queue using a configuration tool. Refer to
Configuration Tools
2. Set the value of 1 > Clr Event Queue to Enable, and then press
Enter to clear the event queue.
Figure 4.3 Reset Event Queue in HyperTerminal
Press the UP ARROW or DOWN ARROW key to scroll
through the parameter list. Press the LEFT ARROW or
RIGHT ARROW key to modify parameter values. Press
the ENTER key to save a new value.
1> Clr Event Queue = Enable
in
Chapter
3.
Troubleshooting
4-5

Hide quick links: