139495_Rev_C GF 300 DV IPI 9/11/12
GF 300 DV IPI

Specifications

Input Rates
Natural Gas
2 6,000 BTU/hr. maximum input
15,000 BTU/hr. minimum input
Propane
2 4,000 BTU/hr. maximum input
12,000 BTU/hr. minimum input
Inlet Pressure:
MIN
Natural Gas:
4.80 WC (1.24 kPa) 7.0 WC (1.74 kPa)
Propane:
12.0 WC (2.99 kPa) 14.0 WC (3.48 kPa)
Manifold Pressure:
MIN
Natural Gas:
1.2 WC (.30 kPa) 3.80 WC (.95 kPa)
Propane:
2.9 WC (.72 kPa) 11.0 WC (2.74 kPa)
• SIT Pro Flame 2 Intermitent Pilot Ignition - 120V / 60 Hz
• Steady State Efficiency: 70.5% NG / 72.3% LP
• AFUE Efficiency:
• CSA P4. 1-02 Fireplace Efficiency:
NG - 66.6% LP - 66.1%
• Factory Air Shutter Settings: NG - 1/8" LP - 3/16"
• Continuous Pilot Ignition Mode ( CPI) may also be used
• Power Requirement: 120 VAC, 4 amps for
IFC Module, optional Blower and Accent Lamp.
Back-up Battery Pack: 4, AA - 1.5V
• Remote Control Transmitter batteries: 3, AAA - 1.5V
• Ambient Temperature Range: 32 -122°F (0 - 50°C)
• Remote Radio Frequency: 315 MHz
C L
4
MAX
MAX
67.7% NG / 67.4% LP

General Information

THIS HEATER MUST BE INSTALLED AND MAINTAINED
BY A QUALIFIED SERVICE AGENCY.
The installation and repair of this appliance must be
done by a qualified service person. Failure to properly
install and maintain this heater could result in an
unsafe or hazardous installation, which may result in
a fire, explosion, property damage, personal injury or
loss of life.
This appliance should be inspected before use and
at least annually. More frequent cleaning may be
required due to excessive lint from carpeting, bedding
material, etc. It is imperative that control compart-
ments, burners, and circulating air passageways of
the appliance be kept clean. See Maintenance, page
26, for details.
THIS APPLIANCE MUST NOT BE CONNECTED TO A
CHIMNEY OR FLUE SERVING ANY OTHER APPLIANCE.
The installation must conform to local codes. Your lo-
cal Jøtul dealer can assist you in determining what is
required in your area for a safe and legal installation.
Some areas require a permit to install a gas burning
appliance. Always consult your local building inspec-
tor, or authority having jurisdiction, to determine
what regulations apply in your area.
CODE COMPLIANCE : Your local officials have final
authority in determining if a proposed installation is
acceptable. Any requirement that is requested by the
local authority having jurisdiction, that is not specifi-
cally addressed in this manual, defaults to local code.
In the absence of local codes, the installation re-
quirements must comply with the current edition of
National codes. In the U.S., these requirements are es-
tablished in the National Fuel Code, ANSI Z223.1.(NFPA
54) current edition. In Canada, the codes have been
established in CAN/CGA B149 Fuel Installation Code,
current edition..